Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom. (8th May 2016)
- Record Type:
- Journal Article
- Title:
- Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom. (8th May 2016)
- Main Title:
- Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom
- Authors:
- Wang, Zhiyue J.
Seo, Youngseob
Babcock, Evelyn
Huang, Hao
Bluml, Stefan
Wisnowski, Jessica
Holshouser, Barbara
Panigrahy, Ashok
Shaw, Dennis W.W.
Altman, Nolan
McColl, Roderick W.
Rollins, Nancy K. - Abstract:
- Abstract : The purpose of this study was to explore the feasibility of assessing quality of diffusion tensor imaging (DTI) from multiple sites and vendors using American College of Radiology (ACR) phantom. Participating sites (Siemens ( n = 2 ), GE ( n = 2 ), and Philips ( n = 4 ) ) reached consensus on parameters for DTI and used the widely available ACR phantom. Tensor data were processed at one site. B 0 and eddy current distortions were assessed using grid line displacement on phantom Slice 5; signal‐to‐noise ratio (SNR) was measured at the center and periphery of the b = 0 image; fractional anisotropy (FA) and mean diffusivity (MD) were assessed using phantom Slice 7. Variations of acquisition parameters and deviations from specified sequence parameters were recorded. Nonlinear grid line distortion was higher with linear shimming and could be corrected using the 2nd order shimming. Following image registration, eddy current distortion was consistently smaller than acquisition voxel size. SNR was consistently higher in the image periphery than center by a factor of 1.3–2.0. ROI‐based FA ranged from 0.007 to 0.024. ROI‐based MD ranged from 1.90 × 10 − 3 to 2.33 × 10 − 3 mm 2 / s ( median = 2.04 × 10 − 3 mm 2 / s ) . Two sites had image void artifacts. The ACR phantom can be used to compare key quality measures of diffusion images acquired from multiple vendors at multiple sites. PACS number(s): 87.57.‐s, 87.19.lf
- Is Part Of:
- Journal of applied clinical medical physics. Volume 17:Number 3(2016)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 17:Number 3(2016)
- Issue Display:
- Volume 17, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 3
- Issue Sort Value:
- 2016-0017-0003-0000
- Page Start:
- 442
- Page End:
- 451
- Publication Date:
- 2016-05-08
- Subjects:
- diffusion tensor imaging -- quality control -- multicenter -- image artifacts
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v17i3.5972 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8622.xml