A comparison of organs at risk doses in GYN intracavitary brachytherapy for different tandem lengths and bladder volumes. (8th May 2016)
- Record Type:
- Journal Article
- Title:
- A comparison of organs at risk doses in GYN intracavitary brachytherapy for different tandem lengths and bladder volumes. (8th May 2016)
- Main Title:
- A comparison of organs at risk doses in GYN intracavitary brachytherapy for different tandem lengths and bladder volumes
- Authors:
- Siavashpour, Zahra
Aghamiri, Mahmoud Reza
Jaberi, Ramin
ZareAkha, Naser
Manshadi, Hamid Reza Dehghan
Kirisits, Christian
Sedaghat, Mahbod - Abstract:
- Abstract : The purpose of this study was to investigate the concurrent effects of tandem length and bladder volume on dose to pelvic organs at risk (OARs) in HDR intracavitary brachytherapy treatment of cervical cancer. Twenty patients with locally advanced cervical cancer were selected for brachytherapy using Rotterdam applicators. The patients were CT scanned twice with empty and full bladder. Two treatment plans were prepared on each of the image sets. Patients were categorized into two groups; those treated with a tandem length of 4 cm or smaller ( T ≤ 4 cm ) and those with tandem length larger than 4 cm ( T > 4 cm ). Only one tandem tip angle of 30° was studied. Dose‐volume histograms (DVHs) of OARs were calculated and compared. Bladder dose was significantly affected by both bladder volume and tandem physical length for T ≤ 4 cm . This was reflected on the values obtained for D 2 cm 3, D 1 cm 3, and D 0.1 cm 3 for both empty and full bladder cases. When T > 4 cm, no correlation could be established between variations in bladder dose and bladder volume. Rectum dose was generally lower when the bladder was empty and T > 4 cm . Dose to sigmoid was increased when T > 4 cm ; this increase was larger when the bladder was full. Our results suggest that, for tandems longer than 4 cm, keeping the bladder empty may reduce the dose to rectum and sigmoid. This is contrary to cases where a shorter than 4 cm tandem is used in which a full bladder (about 50–120 cm 3 )Abstract : The purpose of this study was to investigate the concurrent effects of tandem length and bladder volume on dose to pelvic organs at risk (OARs) in HDR intracavitary brachytherapy treatment of cervical cancer. Twenty patients with locally advanced cervical cancer were selected for brachytherapy using Rotterdam applicators. The patients were CT scanned twice with empty and full bladder. Two treatment plans were prepared on each of the image sets. Patients were categorized into two groups; those treated with a tandem length of 4 cm or smaller ( T ≤ 4 cm ) and those with tandem length larger than 4 cm ( T > 4 cm ). Only one tandem tip angle of 30° was studied. Dose‐volume histograms (DVHs) of OARs were calculated and compared. Bladder dose was significantly affected by both bladder volume and tandem physical length for T ≤ 4 cm . This was reflected on the values obtained for D 2 cm 3, D 1 cm 3, and D 0.1 cm 3 for both empty and full bladder cases. When T > 4 cm, no correlation could be established between variations in bladder dose and bladder volume. Rectum dose was generally lower when the bladder was empty and T > 4 cm . Dose to sigmoid was increased when T > 4 cm ; this increase was larger when the bladder was full. Our results suggest that, for tandems longer than 4 cm, keeping the bladder empty may reduce the dose to rectum and sigmoid. This is contrary to cases where a shorter than 4 cm tandem is used in which a full bladder (about 50–120 cm 3 ) tends to result in a lower dose to rectum and sigmoid. Attention should be given to doses to sigmoid with long tandem lengths, as a larger tandem generally results in a larger dose to sigmoid. PACS number(s): 87.53.Jw … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 17:Number 3(2016)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 17:Number 3(2016)
- Issue Display:
- Volume 17, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 3
- Issue Sort Value:
- 2016-0017-0003-0000
- Page Start:
- 5
- Page End:
- 13
- Publication Date:
- 2016-05-08
- Subjects:
- tandem length -- cervical cancer -- brachytherapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v17i3.5584 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8622.xml