Cytometree: A binary tree algorithm for automatic gating in cytometry analysis. Issue 11 (2nd October 2018)
- Record Type:
- Journal Article
- Title:
- Cytometree: A binary tree algorithm for automatic gating in cytometry analysis. Issue 11 (2nd October 2018)
- Main Title:
- Cytometree: A binary tree algorithm for automatic gating in cytometry analysis
- Authors:
- Commenges, Daniel
Alkhassim, Chariff
Gottardo, Raphael
Hejblum, Boris
Thiébaut, Rodolphe - Abstract:
- Abstract: Flow cytometry is a powerful technology that allows the high‐throughput quantification of dozens of surface and intracellular proteins at the single‐cell level. It has become the most widely used technology for immunophenotyping of cells over the past three decades. Due to the increasing complexity of cytometry experiments (more cells and more markers), traditional manual flow cytometry data analysis has become untenable due to its subjectivity and time‐consuming nature. We present a new unsupervised algorithm called "cytometree " to perform automated population identification (aka gating) in flow cytometry.cytometree is based on the construction of a binary tree, the nodes of which are subpopulations of cells. At each node, the marker distributions are modeled by mixtures of normal distributions. Node splitting is done according to a model selection procedure based on a normalized difference of Akaike information criteria between two competing models. Post‐processing of the tree structure and derived populations allows us to complete the annotation of the populations. The algorithm is shown to perform better than the state‐of‐the‐art unsupervised algorithms previously proposed on panels introduced by the Flow Cytometry: Critical Assessment of Population Identification Methods project. The algorithm is also applied to a T‐cell panel proposed by the Human Immunology Project Consortium (HIPC) program; it also outperforms the best unsupervised open‐source availableAbstract: Flow cytometry is a powerful technology that allows the high‐throughput quantification of dozens of surface and intracellular proteins at the single‐cell level. It has become the most widely used technology for immunophenotyping of cells over the past three decades. Due to the increasing complexity of cytometry experiments (more cells and more markers), traditional manual flow cytometry data analysis has become untenable due to its subjectivity and time‐consuming nature. We present a new unsupervised algorithm called "cytometree " to perform automated population identification (aka gating) in flow cytometry.cytometree is based on the construction of a binary tree, the nodes of which are subpopulations of cells. At each node, the marker distributions are modeled by mixtures of normal distributions. Node splitting is done according to a model selection procedure based on a normalized difference of Akaike information criteria between two competing models. Post‐processing of the tree structure and derived populations allows us to complete the annotation of the populations. The algorithm is shown to perform better than the state‐of‐the‐art unsupervised algorithms previously proposed on panels introduced by the Flow Cytometry: Critical Assessment of Population Identification Methods project. The algorithm is also applied to a T‐cell panel proposed by the Human Immunology Project Consortium (HIPC) program; it also outperforms the best unsupervised open‐source available algorithm while requiring the shortest computation time. © 2018 International Society for Advancement of Cytometry … (more)
- Is Part Of:
- Cytometry. Volume 93:Issue 11(2018)
- Journal:
- Cytometry
- Issue:
- Volume 93:Issue 11(2018)
- Issue Display:
- Volume 93, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 93
- Issue:
- 11
- Issue Sort Value:
- 2018-0093-0011-0000
- Page Start:
- 1132
- Page End:
- 1140
- Publication Date:
- 2018-10-02
- Subjects:
- flow cytometry -- automated gating -- binary tree -- mixture of distributions
Flow cytometry -- Periodicals
Imaging systems in biology -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnostic imaging -- Periodicals
571.605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4930 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cyto.a.23601 ↗
- Languages:
- English
- ISSNs:
- 1552-4922
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8614.xml