Methodology for evaluating and comparing flow cytometers: A multisite study of 23 instruments. Issue 11 (23rd September 2018)
- Record Type:
- Journal Article
- Title:
- Methodology for evaluating and comparing flow cytometers: A multisite study of 23 instruments. Issue 11 (23rd September 2018)
- Main Title:
- Methodology for evaluating and comparing flow cytometers: A multisite study of 23 instruments
- Authors:
- Parks, David R.
Moore, Wayne A.
Brinkman, Ryan R.
Chen, Yong
Condello, Danilo
El Khettabi, Faysal
Nolan, John P.
Perfetto, Stephen P.
Redelman, Doug
Spidlen, Josef
Van Dyke, Jonathan
Wang, Lili
Wood, James C. S. - Abstract:
- Abstract: We demonstrate improved methods for making valid and accurate comparisons of fluorescence measurement capabilities among instruments tested at different sites and times. We designed a suite of measurements and automated data processing methods to obtain consistent objective results and applied them to a selection of 23 instruments at nine sites to provide a range of instruments as well as multiple instances of similar instruments. As far as we know, this study represents the most accurate methods and results so far demonstrated for this purpose. The first component of the study reporting improved methods for photoelectron scale (Spe) evaluations, which was published previously (Parks, El Khettabi, Chase, Hoffman, Perfetto, Spidlen, Wood, Moore, and Brinkman: Cytometry A 91 (2017) 232–249). Those results which were within themselves are not sufficient for instrument comparisons, so here, we use the Spe scale results for the 23 cytometers and combine them with additional information from the analysis suite to obtain the metrics actually needed for instrument evaluations and comparisons. We adopted what we call the 2+2SD limit of resolution as a maximally informative metric, for evaluating and comparing dye measurement sensitivity among different instruments and measurement channels. Our results demonstrate substantial differences among different classes of instruments in both dye response and detection sensitivity and some surprisingly large differences among similarAbstract: We demonstrate improved methods for making valid and accurate comparisons of fluorescence measurement capabilities among instruments tested at different sites and times. We designed a suite of measurements and automated data processing methods to obtain consistent objective results and applied them to a selection of 23 instruments at nine sites to provide a range of instruments as well as multiple instances of similar instruments. As far as we know, this study represents the most accurate methods and results so far demonstrated for this purpose. The first component of the study reporting improved methods for photoelectron scale (Spe) evaluations, which was published previously (Parks, El Khettabi, Chase, Hoffman, Perfetto, Spidlen, Wood, Moore, and Brinkman: Cytometry A 91 (2017) 232–249). Those results which were within themselves are not sufficient for instrument comparisons, so here, we use the Spe scale results for the 23 cytometers and combine them with additional information from the analysis suite to obtain the metrics actually needed for instrument evaluations and comparisons. We adopted what we call the 2+2SD limit of resolution as a maximally informative metric, for evaluating and comparing dye measurement sensitivity among different instruments and measurement channels. Our results demonstrate substantial differences among different classes of instruments in both dye response and detection sensitivity and some surprisingly large differences among similar instruments, even among instruments with nominally identical configurations. On some instruments, we detected defective measurement channels needing service. The system can be applied in shared resource laboratories and other facilities as an aspect of quality assurance, and accurate instrument comparisons can be valuable for selecting instruments for particular purposes and for making informed instrument acquisition decisions. An institutionally supported program could serve the cytometry community by facilitating access to materials, and analysis and maintaining an archive of results. © 2018 International Society for Advancement of Cytometry … (more)
- Is Part Of:
- Cytometry. Volume 93:Issue 11(2018)
- Journal:
- Cytometry
- Issue:
- Volume 93:Issue 11(2018)
- Issue Display:
- Volume 93, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 93
- Issue:
- 11
- Issue Sort Value:
- 2018-0093-0011-0000
- Page Start:
- 1087
- Page End:
- 1091
- Publication Date:
- 2018-09-23
- Subjects:
- flow cytometry -- instrumentation -- standardization -- sensitivity -- automated data analysis -- photoelectron scale -- LED -- microspheres -- resolution limit -- limit of detection
Flow cytometry -- Periodicals
Imaging systems in biology -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnostic imaging -- Periodicals
571.605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4930 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cyto.a.23605 ↗
- Languages:
- English
- ISSNs:
- 1552-4922
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8614.xml