Compression of CT sinogram data by decimation in the view direction. Issue 9 (13th September 2017)
- Record Type:
- Journal Article
- Title:
- Compression of CT sinogram data by decimation in the view direction. Issue 9 (13th September 2017)
- Main Title:
- Compression of CT sinogram data by decimation in the view direction
- Authors:
- Sjölin, Martin
Danielsson, Mats - Abstract:
- Abstract : Pupose: In clinical computed tomography (CT), the image data is acquired during continuous rotation. If the time during which the signal is integrated (the frame time) is too long, the data is blurred in the view direction (i.e., azimuthal blur). This can be overcome by having a high angular sampling rate, but for systems with limited bandwidth, the increased amount of data can be a problem. In this paper, we evaluate the benefit of maintaining a high angular sampling rate on the CT gantry and performing a decimation (digital low‐pass filtration followed by a downsampling) in the view direction before the bottleneck of the data transfer chain. Methods: A theoretical evaluation of the effects of the decimation is presented and the implementation of the digital filter is discussed. The compression scheme is evaluated on image data of a CATPHAN ® 504 phantom and a human skull phantom. Results: It is shown that digital decimation can be used to compress data before read‐out with more remaining data fidelity compared to having longer frame times. Specifically, the method is shown to preserve the detail in the reconstruction of the CATPHAN resolution patterns and the human skull phantom. It is also demonstrated that the method can be used to prevent aliasing artifacts. Conclusions: Decimation in the view direction is presented as an alternative to increasing the frame time for CT systems with limited bandwidth of the data read‐out. The method can be used toAbstract : Pupose: In clinical computed tomography (CT), the image data is acquired during continuous rotation. If the time during which the signal is integrated (the frame time) is too long, the data is blurred in the view direction (i.e., azimuthal blur). This can be overcome by having a high angular sampling rate, but for systems with limited bandwidth, the increased amount of data can be a problem. In this paper, we evaluate the benefit of maintaining a high angular sampling rate on the CT gantry and performing a decimation (digital low‐pass filtration followed by a downsampling) in the view direction before the bottleneck of the data transfer chain. Methods: A theoretical evaluation of the effects of the decimation is presented and the implementation of the digital filter is discussed. The compression scheme is evaluated on image data of a CATPHAN ® 504 phantom and a human skull phantom. Results: It is shown that digital decimation can be used to compress data before read‐out with more remaining data fidelity compared to having longer frame times. Specifically, the method is shown to preserve the detail in the reconstruction of the CATPHAN resolution patterns and the human skull phantom. It is also demonstrated that the method can be used to prevent aliasing artifacts. Conclusions: Decimation in the view direction is presented as an alternative to increasing the frame time for CT systems with limited bandwidth of the data read‐out. The method can be used to either remove aliasing artifacts or preserve spatial resolution. The proposed compression scheme can be implemented on the CT gantry and thus reduce the bandwidth requirements on the data transfer. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 9(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 9(2017)
- Issue Display:
- Volume 44, Issue 9 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 9
- Issue Sort Value:
- 2017-0044-0009-0000
- Page Start:
- e138
- Page End:
- e146
- Publication Date:
- 2017-09-13
- Subjects:
- compression -- computed tomography -- decimation -- FIR filter -- low‐pass filter -- sinogram
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12181 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8606.xml