Investigating simulation‐based metrics for characterizing linear iterative reconstruction in digital breast tomosynthesis. Issue 9 (13th September 2017)
- Record Type:
- Journal Article
- Title:
- Investigating simulation‐based metrics for characterizing linear iterative reconstruction in digital breast tomosynthesis. Issue 9 (13th September 2017)
- Main Title:
- Investigating simulation‐based metrics for characterizing linear iterative reconstruction in digital breast tomosynthesis
- Authors:
- Rose, Sean D.
Sanchez, Adrian A.
Sidky, Emil Y.
Pan, Xiaochuan - Abstract:
- Abstract : Purpose: Simulation‐based image quality metrics are adapted and investigated for characterizing the parameter dependences of linear iterative image reconstruction for DBT. Methods: Three metrics based on a 2D DBT simulation are investigated: (1) a root‐mean‐square‐error (RMSE) between the test phantom and reconstructed image, (2) a gradient RMSE where the comparison is made after taking a spatial gradient of both image and phantom, and (3) a region‐of‐interest (ROI) Hotelling observer (HO) for signal‐known‐exactly/background‐known‐exactly (SKE/BKE) and signal‐known‐exactly/background‐known‐statistically (SKE/BKS) detection tasks. Two simulation studies are performed using the aforementioned metrics, varying voxel aspect ratio, and regularization strength for two types of Tikhonov‐regularized least‐squares optimization. The RMSE metrics are applied to a 2D test phantom with resolution bar patterns at varying angles, and the ROI‐HO metric is applied to two tasks relevant to DBT: lesion detection, modeled by use of a large, low‐contrast signal, and microcalcification detection, modeled by use of a small, high‐contrast signal. The RMSE metric trends are compared with visual assessment of the reconstructed bar‐pattern phantom. The ROI‐HO metric trends are compared with 3D reconstructed images from ACR phantom data acquired with a Hologic Selenia Dimensions DBT system. Results: Sensitivity of the image RMSE to mean pixel value is found to limit its applicability to theAbstract : Purpose: Simulation‐based image quality metrics are adapted and investigated for characterizing the parameter dependences of linear iterative image reconstruction for DBT. Methods: Three metrics based on a 2D DBT simulation are investigated: (1) a root‐mean‐square‐error (RMSE) between the test phantom and reconstructed image, (2) a gradient RMSE where the comparison is made after taking a spatial gradient of both image and phantom, and (3) a region‐of‐interest (ROI) Hotelling observer (HO) for signal‐known‐exactly/background‐known‐exactly (SKE/BKE) and signal‐known‐exactly/background‐known‐statistically (SKE/BKS) detection tasks. Two simulation studies are performed using the aforementioned metrics, varying voxel aspect ratio, and regularization strength for two types of Tikhonov‐regularized least‐squares optimization. The RMSE metrics are applied to a 2D test phantom with resolution bar patterns at varying angles, and the ROI‐HO metric is applied to two tasks relevant to DBT: lesion detection, modeled by use of a large, low‐contrast signal, and microcalcification detection, modeled by use of a small, high‐contrast signal. The RMSE metric trends are compared with visual assessment of the reconstructed bar‐pattern phantom. The ROI‐HO metric trends are compared with 3D reconstructed images from ACR phantom data acquired with a Hologic Selenia Dimensions DBT system. Results: Sensitivity of the image RMSE to mean pixel value is found to limit its applicability to the assessment of DBT image reconstruction. The image gradient RMSE is insensitive to mean pixel value and appears to track better with subjective visualization of the reconstructed bar‐pattern phantom. The ROI‐HO metric shows an increasing trend with regularization strength for both forms of Tikhonov‐regularized least‐squares; however, this metric saturates at intermediate regularization strength indicating a point of diminishing returns for signal detection. Visualization with the reconstructed ACR phantom images appear to show a similar dependence with regularization strength. Conclusions: From the limited studies presented it appears that image gradient RMSE trends correspond with visual assessment better than image RMSE for DBT image reconstruction. The ROI‐HO metric for both detection tasks also appears to reflect visual trends in the ACR phantom reconstructions as a function of regularization strength. We point out, however, that the true utility of these metrics can only be assessed after amassing more data. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 9(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 9(2017)
- Issue Display:
- Volume 44, Issue 9 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 9
- Issue Sort Value:
- 2017-0044-0009-0000
- Page Start:
- e279
- Page End:
- e296
- Publication Date:
- 2017-09-13
- Subjects:
- digital breast tomosynthesis -- Hotelling observer -- image reconstruction -- model observers -- signal detection
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12445 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8606.xml