Evaluating the analytical performance of five new coagulation assays for the measurement of prothrombin time and activated thromboplastin time. (22nd July 2018)
- Record Type:
- Journal Article
- Title:
- Evaluating the analytical performance of five new coagulation assays for the measurement of prothrombin time and activated thromboplastin time. (22nd July 2018)
- Main Title:
- Evaluating the analytical performance of five new coagulation assays for the measurement of prothrombin time and activated thromboplastin time
- Authors:
- Kitchen, Steve
Geisen, Ulrich
Kappelmayer, Janos
Quehenberger, Peter
Drieß, Julia
Lowe, Anna
Jones, Robert
Boehm, Jana G.
Miles, Gabrielle
Rozsnyai, Gergely - Abstract:
- Abstract: Introduction: New methods for coagulation tests require careful assessment before routine use. We evaluated the analytical performance of five new coagulation assays for measuring prothrombin time (PT) and activated partial thromboplastin time (aPTT). Methods: PT Rec, PT Owren, aPTT, aPTT Lupus and aPTT Screen assays (Roche Diagnostics) were evaluated oncobas t 711 andcobas t 511 analysers (Roche Diagnostics) at four European centres. Analytical performance and method comparisons with relevant commercially available assays were performed to Clinical Laboratory Standards Institute guidelines using residual anonymized samples. Lot‐to‐lot comparison and equivalency of thecobas t analysers were also assessed; reference ranges were determined using samples from apparently healthy volunteers. Results: Overall, coefficients of variation were ≤1.3% for within‐run precision and ≤6.3% for total reproducibility across all sites. Deming regression analyses showed good agreement between each assay (cobas t 711) and respective comparator method (Pearson's r : 0.964‐0.999, n > 120 samples/assay/site). Passing–Bablok regression analyses demonstrated equivalence of the twocobas t platforms for use with each assay (Pearson's r ≥ 0.995). Lot‐to‐lot consistency was high for all assays and comparisons (Pearson's r ≥ 0.998). Reference ranges (2.5th‐97.5th percentiles; n = 200 samples/assay) in seconds were 8.4‐10.6 (PT Rec), 18.2‐27.2 (PT Owren), 23.6‐30.6 (aPTT), 24.1‐31.7 (aPTTAbstract: Introduction: New methods for coagulation tests require careful assessment before routine use. We evaluated the analytical performance of five new coagulation assays for measuring prothrombin time (PT) and activated partial thromboplastin time (aPTT). Methods: PT Rec, PT Owren, aPTT, aPTT Lupus and aPTT Screen assays (Roche Diagnostics) were evaluated oncobas t 711 andcobas t 511 analysers (Roche Diagnostics) at four European centres. Analytical performance and method comparisons with relevant commercially available assays were performed to Clinical Laboratory Standards Institute guidelines using residual anonymized samples. Lot‐to‐lot comparison and equivalency of thecobas t analysers were also assessed; reference ranges were determined using samples from apparently healthy volunteers. Results: Overall, coefficients of variation were ≤1.3% for within‐run precision and ≤6.3% for total reproducibility across all sites. Deming regression analyses showed good agreement between each assay (cobas t 711) and respective comparator method (Pearson's r : 0.964‐0.999, n > 120 samples/assay/site). Passing–Bablok regression analyses demonstrated equivalence of the twocobas t platforms for use with each assay (Pearson's r ≥ 0.995). Lot‐to‐lot consistency was high for all assays and comparisons (Pearson's r ≥ 0.998). Reference ranges (2.5th‐97.5th percentiles; n = 200 samples/assay) in seconds were 8.4‐10.6 (PT Rec), 18.2‐27.2 (PT Owren), 23.6‐30.6 (aPTT), 24.1‐31.7 (aPTT Lupus) and 23.9‐33.2 (aPTT Screen). Conclusion: Based on the excellent analytical performance and good agreement with relevant comparator methods, the five coagulation assays on the novelcobas t 711 andcobas t 511 analysers are suitable for routine use in core laboratories. … (more)
- Is Part Of:
- International journal of laboratory hematology. Volume 40:Number 6(2018:Dec.)
- Journal:
- International journal of laboratory hematology
- Issue:
- Volume 40:Number 6(2018:Dec.)
- Issue Display:
- Volume 40, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 40
- Issue:
- 6
- Issue Sort Value:
- 2018-0040-0006-0000
- Page Start:
- 645
- Page End:
- 654
- Publication Date:
- 2018-07-22
- Subjects:
- activated partial thromboplastin time -- coagulation analyser -- prothrombin time
Hematology -- Periodicals
Blood -- Diseases -- Periodicals
Hematology -- Periodicals
616.15005 - Journal URLs:
- http://firstsearch.oclc.org/FSIP?db=ECO&journal=1751-5521&screen=info&done=referer ↗
http://www.blackwell-synergy.com/loi/clh ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-553X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ijlh.12897 ↗
- Languages:
- English
- ISSNs:
- 1751-5521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.312220
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8606.xml