Near-infrared spectroscopy cerebral oximetry as a predictor of neurological intolerance during carotid artery stenting with proximal protection. (December 2018)
- Record Type:
- Journal Article
- Title:
- Near-infrared spectroscopy cerebral oximetry as a predictor of neurological intolerance during carotid artery stenting with proximal protection. (December 2018)
- Main Title:
- Near-infrared spectroscopy cerebral oximetry as a predictor of neurological intolerance during carotid artery stenting with proximal protection
- Authors:
- Kakumoto, Kohsuke
Harada, Kei
Sankoda, Yukihiro
Taniguchi, Syunsuke
Fukuyama, Kouzou - Abstract:
- Highlights: Carotid artery stenting with proximal protection can expose occlusion intolerance (OI). Near-infrared spectroscopy cerebral oximetry can predict OI with high sensitivity. Distal filter protection should be combined with proximal protection to prevent prolonged neurological symptoms due to OI. Abstract: Carotid artery stenting (CAS) with proximal protection can expose occlusion intolerance (OI) due to ipsilateral cerebral hemisphere hypoperfusion. Near-infrared spectroscopy (NIRS) cerebral oximetry can monitor regional cerebral oxygenation (rSO2 ) in the frontal lobes, and is used during CAS to predict cerebral blood flow insufficiency. The aim of this study was to evaluate rSO2 as a predictor of OI during CAS. We retrospectively examined 146 patients who underwent CAS with proximal protection. An INVOS® NIRS oximeter was used for rSO2 measurement, which was compared with stump pressure (SP) measured by a guiding catheter during occlusion of the common carotid artery (CCA) and external carotid artery. For the lesion with OI, distal filter protection was combined with proximal protection if possible, and CCA was intermittently occluded during the procedure. Twenty-seven patients (18%) developed OI. The relative decrease in NIRS oximeter saturation (ΔrSO2 ) on the ipsilateral side was significantly lower in the OI group than in the tolerance group (14 ± 5.1% vs. 3.4 ± 3.5, p < 0.001). Using ΔrSO2 of 8% as the cutoff value for predicting OI, sensitivity was 92% andHighlights: Carotid artery stenting with proximal protection can expose occlusion intolerance (OI). Near-infrared spectroscopy cerebral oximetry can predict OI with high sensitivity. Distal filter protection should be combined with proximal protection to prevent prolonged neurological symptoms due to OI. Abstract: Carotid artery stenting (CAS) with proximal protection can expose occlusion intolerance (OI) due to ipsilateral cerebral hemisphere hypoperfusion. Near-infrared spectroscopy (NIRS) cerebral oximetry can monitor regional cerebral oxygenation (rSO2 ) in the frontal lobes, and is used during CAS to predict cerebral blood flow insufficiency. The aim of this study was to evaluate rSO2 as a predictor of OI during CAS. We retrospectively examined 146 patients who underwent CAS with proximal protection. An INVOS® NIRS oximeter was used for rSO2 measurement, which was compared with stump pressure (SP) measured by a guiding catheter during occlusion of the common carotid artery (CCA) and external carotid artery. For the lesion with OI, distal filter protection was combined with proximal protection if possible, and CCA was intermittently occluded during the procedure. Twenty-seven patients (18%) developed OI. The relative decrease in NIRS oximeter saturation (ΔrSO2 ) on the ipsilateral side was significantly lower in the OI group than in the tolerance group (14 ± 5.1% vs. 3.4 ± 3.5, p < 0.001). Using ΔrSO2 of 8% as the cutoff value for predicting OI, sensitivity was 92% and specificity was 89%. SP was significantly lower in the OI group than in the tolerance group (22 ± 13 mmHg vs. 40 ± 22 mmHg, p < 0.001). Using SP ≤25 mmHg as the cutoff value for predicting OI, sensitivity was 78% and specificity was 77%. ΔrSO2 was more reliable than SP for predicting OI. Distal filter protection should be combined with proximal protection to prevent prolonged neurological symptoms due to OI. … (more)
- Is Part Of:
- Journal of clinical neuroscience. Volume 58(2018)
- Journal:
- Journal of clinical neuroscience
- Issue:
- Volume 58(2018)
- Issue Display:
- Volume 58, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 58
- Issue:
- 2018
- Issue Sort Value:
- 2018-0058-2018-0000
- Page Start:
- 89
- Page End:
- 93
- Publication Date:
- 2018-12
- Subjects:
- Carotid artery stenting -- Occlusion intolerance -- NIRS cerebral oximetry -- Stump pressure
Brain -- Surgery -- Periodicals
Neurosciences -- Periodicals
Nervous system -- Surgery -- Periodicals
Brain -- surgery -- Periodicals
Neurosurgical Procedures -- Periodicals
Neurosciences -- Periodicals
Electronic journals
616.8 - Journal URLs:
- http://www.harcourt-international.com/journals ↗
http://www.sciencedirect.com/science/journal/09675868 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09675868 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jocn.2018.09.034 ↗
- Languages:
- English
- ISSNs:
- 0967-5868
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.585000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8587.xml