Photon beam attenuation characteristics of three commercial radiation therapy treatment couch-tops. Issue 4 (26th June 2018)
- Record Type:
- Journal Article
- Title:
- Photon beam attenuation characteristics of three commercial radiation therapy treatment couch-tops. Issue 4 (26th June 2018)
- Main Title:
- Photon beam attenuation characteristics of three commercial radiation therapy treatment couch-tops
- Authors:
- Wajid, Hamza
Fleck, Andre
Darko, Johnson
Osei, Ernest - Abstract:
- Abstract: Aim: The purpose of the study was to investigate the detailed angularly dependent attenuation characteristics of three different commercial couch-tops: Varian IGRT, Qfix kVue Standard and Qfix kVue Dose Max couch-tops used in radiation therapy. Materials and methods: The attenuation of photon beams by the treatment couch-tops was measured using a farmer chamber inserted at the centre of a 16 cm diameter cylindrical acrylic phantom for five different photon energies: 6 MV, 6FFF MV, 10 MV, 10FFF MV and 15 MV photon beams. The Varian IGRT couch-top has three different thicknesses thus attenuation measurements were done at the three different longitudinal locations. Measurements were made with the sliding support rails of the Qfix kVue Standard and Qfix kVue Dose Max couch-tops at both 'rails-in' and 'rails-out' positions. All measurements were taken for several projections through 360° movement of the gantry and for two different field sizes; 5×5 cm 2 and 10×10 cm 2 . Results and findings: The results indicate that the maximum attenuation of the Varian IGRT couch-top at the thin, medium and thick portions are 5·1, 5·7 and 8·9%, respectively, the Qfix kVue Standard couch with the rails-in and rails-out are 11·2 and 13·7%, respectively, and Qfix kVue Dose Max couch-top with rails-in and rails-out are 9·7 and 13·8%, respectively. The results from this study can be used to account for the couch-top attenuation during radiation treatment planning of patients treated withAbstract: Aim: The purpose of the study was to investigate the detailed angularly dependent attenuation characteristics of three different commercial couch-tops: Varian IGRT, Qfix kVue Standard and Qfix kVue Dose Max couch-tops used in radiation therapy. Materials and methods: The attenuation of photon beams by the treatment couch-tops was measured using a farmer chamber inserted at the centre of a 16 cm diameter cylindrical acrylic phantom for five different photon energies: 6 MV, 6FFF MV, 10 MV, 10FFF MV and 15 MV photon beams. The Varian IGRT couch-top has three different thicknesses thus attenuation measurements were done at the three different longitudinal locations. Measurements were made with the sliding support rails of the Qfix kVue Standard and Qfix kVue Dose Max couch-tops at both 'rails-in' and 'rails-out' positions. All measurements were taken for several projections through 360° movement of the gantry and for two different field sizes; 5×5 cm 2 and 10×10 cm 2 . Results and findings: The results indicate that the maximum attenuation of the Varian IGRT couch-top at the thin, medium and thick portions are 5·1, 5·7 and 8·9%, respectively, the Qfix kVue Standard couch with the rails-in and rails-out are 11·2 and 13·7%, respectively, and Qfix kVue Dose Max couch-top with rails-in and rails-out are 9·7 and 13·8%, respectively. The results from this study can be used to account for the couch-top attenuation during radiation treatment planning of patients treated with these couch-tops. … (more)
- Is Part Of:
- Journal of radiotherapy in practice. Volume 17:Issue 4(2018)
- Journal:
- Journal of radiotherapy in practice
- Issue:
- Volume 17:Issue 4(2018)
- Issue Display:
- Volume 17, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 17
- Issue:
- 4
- Issue Sort Value:
- 2018-0017-0004-0000
- Page Start:
- 377
- Page End:
- 383
- Publication Date:
- 2018-06-26
- Subjects:
- photon beam attenuation, -- varian IGRT couch-top, -- qfix kVue couch top, -- treatment couch top, -- treatment planning
Radiotherapy -- Periodicals
615.842005 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=JRP ↗
- DOI:
- 10.1017/S1460396918000158 ↗
- Languages:
- English
- ISSNs:
- 1460-3969
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 8553.xml