An evaluation of three commercially available metal artifact reduction methods for CT imaging. (13th January 2015)
- Record Type:
- Journal Article
- Title:
- An evaluation of three commercially available metal artifact reduction methods for CT imaging. (13th January 2015)
- Main Title:
- An evaluation of three commercially available metal artifact reduction methods for CT imaging
- Authors:
- Huang, Jessie Y
Kerns, James R
Nute, Jessica L
Liu, Xinming
Balter, Peter A
Stingo, Francesco C
Followill, David S
Mirkovic, Dragan
Howell, Rebecca M
Kry, Stephen F - Abstract:
- Abstract: Three commercial metal artifact reduction methods were evaluated for use in computed tomography (CT) imaging in the presence of clinically realistic metal implants: Philips O-MAR, GE's monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI monochromatic imaging with metal artifact reduction software applied (MARs). Each method was evaluated according to CT number accuracy, metal size accuracy, and streak artifact severity reduction by using several phantoms, including three anthropomorphic phantoms containing metal implants (hip prosthesis, dental fillings and spinal fixation rods). All three methods showed varying degrees of success for the hip prosthesis and spinal fixation rod cases, while none were particularly beneficial for dental artifacts. Limitations of the methods were also observed. MARs underestimated the size of metal implants and introduced new artifacts in imaging planes beyond the metal implant when applied to dental artifacts, and both the O-MAR and MARs algorithms induced artifacts for spinal fixation rods in a thoracic phantom. Our findings suggest that all three artifact mitigation methods may benefit patients with metal implants, though they should be used with caution in certain scenarios.
- Is Part Of:
- Physics in medicine & biology. Volume 60:Number 3(2015:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 60:Number 3(2015:Feb.)
- Issue Display:
- Volume 60, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 60
- Issue:
- 3
- Issue Sort Value:
- 2015-0060-0003-0000
- Page Start:
- 1047
- Page End:
- 1067
- Publication Date:
- 2015-01-13
- Subjects:
- computed tomography -- metal artifact reduction -- dual-energy CT
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/60/3/1047 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8553.xml