Attachment of upper arm prostheses with a subcutaneous osseointegrated implant in transhumeral amputees. (February 2018)
- Record Type:
- Journal Article
- Title:
- Attachment of upper arm prostheses with a subcutaneous osseointegrated implant in transhumeral amputees. (February 2018)
- Main Title:
- Attachment of upper arm prostheses with a subcutaneous osseointegrated implant in transhumeral amputees
- Authors:
- Salminger, Stefan
Gradischar, Andreas
Skiera, Richard
Roche, Aidan D
Sturma, Agnes
Hofer, Christian
Aszmann, Oskar C - Abstract:
- Background: The stump–socket interface is of utmost importance for prosthetic function in transhumeral amputees. Stability of this connection may be improved using a newly designed subcutaneous implant. Objectives: The purpose was to determine the effect of the implant together with customized socket designs on the range of motion of the shoulder and the prosthetic function compared to conventional fitting. Study design: Case series. Methods: The range of motion was measured with scaled metrics and the prosthetic function evaluated with the Southampton Hand Assessment Procedure and the Box and Block Test. Maximal loading was measured in straight and 90° flexion of the elbow. Results: The restriction of range of motion after conventional fitting was decreased from 42.55% ± 6.56% to 9.23% ± 14.89% in Patient I and from 62.18% ± 15.19% to 2.51% ± 2.49% in Patient II using the implant with customized sockets compared to range of motion without prosthesis. Both patients showed improved prosthetic function with the new system compared to conventional fitting. Conclusion: The presented subcutaneous humeral implant, together with customized socket designs without straps and harnesses to the contralateral shoulder, can maintain almost complete range of motion of the shoulder. This resulted in improved prosthetic function and comfort for the patient without constant risk of infection. Clinical relevance: Discomfort and limited prosthetic function are the main reasons for abandonmentBackground: The stump–socket interface is of utmost importance for prosthetic function in transhumeral amputees. Stability of this connection may be improved using a newly designed subcutaneous implant. Objectives: The purpose was to determine the effect of the implant together with customized socket designs on the range of motion of the shoulder and the prosthetic function compared to conventional fitting. Study design: Case series. Methods: The range of motion was measured with scaled metrics and the prosthetic function evaluated with the Southampton Hand Assessment Procedure and the Box and Block Test. Maximal loading was measured in straight and 90° flexion of the elbow. Results: The restriction of range of motion after conventional fitting was decreased from 42.55% ± 6.56% to 9.23% ± 14.89% in Patient I and from 62.18% ± 15.19% to 2.51% ± 2.49% in Patient II using the implant with customized sockets compared to range of motion without prosthesis. Both patients showed improved prosthetic function with the new system compared to conventional fitting. Conclusion: The presented subcutaneous humeral implant, together with customized socket designs without straps and harnesses to the contralateral shoulder, can maintain almost complete range of motion of the shoulder. This resulted in improved prosthetic function and comfort for the patient without constant risk of infection. Clinical relevance: Discomfort and limited prosthetic function are the main reasons for abandonment especially in transhumeral amputees. Shoulder straps and harnesses within conventional socket designs may not only lead to pain and skin irritations at the contralateral shoulder but also limit the range of motion of the shoulder joint and therefore prosthetic function. … (more)
- Is Part Of:
- Prosthetics and orthotics international. Volume 42:Number 1(2018)
- Journal:
- Prosthetics and orthotics international
- Issue:
- Volume 42:Number 1(2018)
- Issue Display:
- Volume 42, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2018-0042-0001-0000
- Page Start:
- 93
- Page End:
- 100
- Publication Date:
- 2018-02
- Subjects:
- Biomechanics -- implant -- osseointegration -- prosthetic interface mechanics -- prosthetics -- rehabilitation -- rehabilitation of amputees -- transhumeral amputation
Orthopedic apparatus -- Periodicals
Prosthesis -- Periodicals
Implants, Artificial -- Periodicals
617.905 - Journal URLs:
- http://poi.sagepub.com/content/by/year ↗
https://journals.lww.com/poijournal/pages/default.aspx ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/poi ↗
http://www.tandf.co.uk/journals/titles/03093646.asp ↗ - DOI:
- 10.1177/0309364616665732 ↗
- Languages:
- English
- ISSNs:
- 0309-3646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6935.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8550.xml