Photoelastic analysis of stress distributions in the root–bone interface when applying various orthodontic methods to subside lower anterior crowding. (October 2018)
- Record Type:
- Journal Article
- Title:
- Photoelastic analysis of stress distributions in the root–bone interface when applying various orthodontic methods to subside lower anterior crowding. (October 2018)
- Main Title:
- Photoelastic analysis of stress distributions in the root–bone interface when applying various orthodontic methods to subside lower anterior crowding
- Authors:
- Chiang, Pao-Chang
Lin, Shu-Li
Liu, Ming-Jung
Fan, Kan-Hsin
Chang, Wei-Jen
Lee, Sheng-Yang
Huang, Haw-Ming - Abstract:
- Dental crowding is a prevalent problem in modern society. Various factors, including different bracket systems and geometry of wire, influence the outcome using superelastic wire in the alignment stage of treatment. Currently, the use of light round wire instead of large-sized rectangular wire is emphasized to avoid powerful torsional stiffness. However, these guidelines lack scientific evidence for support. They have been written predominantly based on clinical experience. Therefore, the purpose of this study was to evaluate how factors such as bracket systems and wire geometry affect the stress distribution at the root–bone interface. Models using a photoelastic material (PL-3) to simulate bone tissue were fabricated. The simulated teeth were arranged as in lower anterior crowding. Then, the crowded teeth were subjected to orthodontic treatment with various types of bracket, ligating approaches using ligature wires of different sizes, shapes, and materials. Photoelastic images of the bone area of the models were obtained and compared. The results showed that wire size plays a more significant role than the material or cross-sectional shape of the wire in affecting the stress distribution at the simulated root–bone interface. The teeth ligated with a larger cross-sectional diameter of wire showed the application of excessive torque, which may cause root resorption and slow down tooth movement. These results not only demonstrate the scientific evidence backing clinicalDental crowding is a prevalent problem in modern society. Various factors, including different bracket systems and geometry of wire, influence the outcome using superelastic wire in the alignment stage of treatment. Currently, the use of light round wire instead of large-sized rectangular wire is emphasized to avoid powerful torsional stiffness. However, these guidelines lack scientific evidence for support. They have been written predominantly based on clinical experience. Therefore, the purpose of this study was to evaluate how factors such as bracket systems and wire geometry affect the stress distribution at the root–bone interface. Models using a photoelastic material (PL-3) to simulate bone tissue were fabricated. The simulated teeth were arranged as in lower anterior crowding. Then, the crowded teeth were subjected to orthodontic treatment with various types of bracket, ligating approaches using ligature wires of different sizes, shapes, and materials. Photoelastic images of the bone area of the models were obtained and compared. The results showed that wire size plays a more significant role than the material or cross-sectional shape of the wire in affecting the stress distribution at the simulated root–bone interface. The teeth ligated with a larger cross-sectional diameter of wire showed the application of excessive torque, which may cause root resorption and slow down tooth movement. These results not only demonstrate the scientific evidence backing clinical experience but also can be a useful reference for further clinical application. … (more)
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 232:Number 10(2018:Oct.)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 232:Number 10(2018:Oct.)
- Issue Display:
- Volume 232, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 232
- Issue:
- 10
- Issue Sort Value:
- 2018-0232-0010-0000
- Page Start:
- 999
- Page End:
- 1007
- Publication Date:
- 2018-10
- Subjects:
- Photoelastic -- orthodontic -- teeth crowing -- stress distribution
Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411918796046 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8539.xml