Evaluation of lens absorbed dose with Cone Beam IGRT procedures. (12th October 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of lens absorbed dose with Cone Beam IGRT procedures. (12th October 2015)
- Main Title:
- Evaluation of lens absorbed dose with Cone Beam IGRT procedures
- Authors:
- Palomo, R
Pujades, M C
Gimeno-Olmos, J
Carmona, V
Lliso, F
Candela-Juan, C
Vijande, J
Ballester, F
Perez-Calatayud, J - Abstract:
- Abstract: The purpose of this work is to evaluate the absorbed dose to the eye lenses due to the cone beam computed tomography (CBCT) system used to accurately position the patient during head-and-neck image guided procedures. The on-board imaging (OBI) systems (v.1.5) of Clinac iX and TrueBeam (Varian) accelerators were used to evaluate the imparted dose to the eye lenses and some additional points of the head. All CBCT scans were acquired with the Standard-Dose Head protocol from Varian. Doses were measured using thermoluminescence dosimeters (TLDs) placed in an anthropomorphic phantom. TLDs were calibrated at the beam quality used to reduce their energy dependence. Average dose to the lens due to the OBI systems of the Clinac iX and the TrueBeam were 0.71 ± 0.07 mGy/CBCT and 0.70 ± 0.08 mGy/CBCT, respectively. The extra absorbed dose received by the eye lenses due to one CBCT acquisition with the studied protocol is far below the 500 mGy threshold established by ICRP for cataract formation (ICRP 2011 Statement on Tissue Reactions ). However, the incremental effect of several CBCT acquisitions during the whole treatment should be taken into account.
- Is Part Of:
- Journal of radiological protection. Volume 35:Number 4(2015:Dec.)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 35:Number 4(2015:Dec.)
- Issue Display:
- Volume 35, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 35
- Issue:
- 4
- Issue Sort Value:
- 2015-0035-0004-0000
- Page Start:
- N33
- Page End:
- N41
- Publication Date:
- 2015-10-12
- Subjects:
- IGRT -- CBCT -- lens absorbed dose -- TLD
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/0952-4746/35/4/N33 ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8527.xml