Novel Nitinol Stent for Lesions up to 24 cm in the Superficial Femoral and Proximal Popliteal Arteries: 24-Month Results From the TIGRIS Randomized Trial. (February 2018)
- Record Type:
- Journal Article
- Title:
- Novel Nitinol Stent for Lesions up to 24 cm in the Superficial Femoral and Proximal Popliteal Arteries: 24-Month Results From the TIGRIS Randomized Trial. (February 2018)
- Main Title:
- Novel Nitinol Stent for Lesions up to 24 cm in the Superficial Femoral and Proximal Popliteal Arteries: 24-Month Results From the TIGRIS Randomized Trial
- Authors:
- Laird, John R.
Zeller, Thomas
Loewe, Christian
Chamberlin, Jack
Begg, Richard
Schneider, Peter A.
Nanjundappa, Aravinda
Bunch, Frank
Schultz, Scott
Harlin, Stuart
Lansky, Alexandra
Jaff, Michael R. - Abstract:
- Purpose: To evaluate the safety and effectiveness of the TIGRIS stent for lesions up to 24 cm in the superficial femoral and proximal popliteal arteries (SFA/PPA).Methods: This prospective, multicenter, randomized study enrolled 274 subjects at 36 sites in the United States and Europe. Subjects were randomly assigned in a 3:1 ratio to treatment with the TIGRIS stent (n=197; mean age 66.7±9.28 years; 141 men) or LifeStent (n=70; mean age 67.9±8.87 years; 49 men). The primary safety endpoint was 30-day freedom from major adverse events (MAE). The primary efficacy endpoint was primary patency at 12 months. Secondary endpoints included target lesion revascularization (TLR) and stent fracture. Clinical success and quality of life were also assessed.Results: Mean lesion length (107.6 vs 117.9 mm, p=0.29), procedure success (99.5% vs 97.1%, p=0.17), and freedom from MAE (99.5% vs 100%, p>0.99) were similar for the TIGRIS and control groups, respectively. Likewise, there was no difference in primary patency at 12 months (60.6% vs 63.2%, p=0.73) or 24 months (56.3% vs 50.2%, p=0.60) or in TLR at the same time points (76.6% vs 80.6%, p=0.49; 70.5% vs 67.2%, p=0.85). There were no differences in the changes in Rutherford category or the ankle/brachial index through 24 months. The rate of stent fracture was lower for TIGRIS compared with LifeStent (0% vs 32.7%, p<0.001).Conclusion: The TIGRIS stent and LifeStent were similarly effective for the treatment of lesions in the SFA and PPA.Purpose: To evaluate the safety and effectiveness of the TIGRIS stent for lesions up to 24 cm in the superficial femoral and proximal popliteal arteries (SFA/PPA).Methods: This prospective, multicenter, randomized study enrolled 274 subjects at 36 sites in the United States and Europe. Subjects were randomly assigned in a 3:1 ratio to treatment with the TIGRIS stent (n=197; mean age 66.7±9.28 years; 141 men) or LifeStent (n=70; mean age 67.9±8.87 years; 49 men). The primary safety endpoint was 30-day freedom from major adverse events (MAE). The primary efficacy endpoint was primary patency at 12 months. Secondary endpoints included target lesion revascularization (TLR) and stent fracture. Clinical success and quality of life were also assessed.Results: Mean lesion length (107.6 vs 117.9 mm, p=0.29), procedure success (99.5% vs 97.1%, p=0.17), and freedom from MAE (99.5% vs 100%, p>0.99) were similar for the TIGRIS and control groups, respectively. Likewise, there was no difference in primary patency at 12 months (60.6% vs 63.2%, p=0.73) or 24 months (56.3% vs 50.2%, p=0.60) or in TLR at the same time points (76.6% vs 80.6%, p=0.49; 70.5% vs 67.2%, p=0.85). There were no differences in the changes in Rutherford category or the ankle/brachial index through 24 months. The rate of stent fracture was lower for TIGRIS compared with LifeStent (0% vs 32.7%, p<0.001).Conclusion: The TIGRIS stent and LifeStent were similarly effective for the treatment of lesions in the SFA and PPA. The high flexibility and zero fracture rate associated with the TIGRIS stent make this device favorable for use in high-flexion arteries. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 25:Number 1(2018:Feb.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 25:Number 1(2018:Feb.)
- Issue Display:
- Volume 25, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2018-0025-0001-0000
- Page Start:
- 68
- Page End:
- 78
- Publication Date:
- 2018-02
- Subjects:
- femoropopliteal segment -- lesion length -- nitinol stent -- peripheral artery disease -- popliteal artery -- randomized trial -- stent fracture -- superficial femoral artery
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602817749242 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8519.xml