Reduction of Tribocorrosion Products When Using the Platform-Switching Concept. (August 2018)
- Record Type:
- Journal Article
- Title:
- Reduction of Tribocorrosion Products When Using the Platform-Switching Concept. (August 2018)
- Main Title:
- Reduction of Tribocorrosion Products When Using the Platform-Switching Concept
- Authors:
- Alrabeah, G.O.
Knowles, J.C.
Petridis, H. - Abstract:
- The reduced marginal bone loss observed when using the platform-switching concept may be the result of reduced amounts of tribocorrosion products released to the peri-implant tissues. Therefore, the purpose of this study was to compare the tribocorrosion product release from various platform-matched and platform-switched implant-abutment couplings under cyclic loading. Forty-eight titanium implants were coupled with pure titanium, gold alloy, cobalt-chrome alloy, and zirconia abutments forming either platform-switched or platform-matched groups ( n = 6). The specimens were subjected to cyclic occlusal forces in a wet acidic environment for 24 h followed by static aqueous immersion for 6 d. The amount of metal ions released was measured using inductively coupled plasma mass spectrometry. Microscopic evaluations were performed pre- and postimmersion under scanning electron microscope (SEM) equipped with energy-dispersive spectroscopy X-ray for corrosion assessment at the interface and wear particle characterization. All platform-switched groups showed less metal ion release compared with their platform-matched counterparts within each abutment material group ( P < 0.001). Implants connected to platform-matched cobalt-chrome abutments demonstrated the highest total mean metal ion release (218 ppb), while the least total mean ion release (11 ppb) was observed in the implants connected to platform-switched titanium abutments ( P ≤ 0.001). Titanium was released from all testThe reduced marginal bone loss observed when using the platform-switching concept may be the result of reduced amounts of tribocorrosion products released to the peri-implant tissues. Therefore, the purpose of this study was to compare the tribocorrosion product release from various platform-matched and platform-switched implant-abutment couplings under cyclic loading. Forty-eight titanium implants were coupled with pure titanium, gold alloy, cobalt-chrome alloy, and zirconia abutments forming either platform-switched or platform-matched groups ( n = 6). The specimens were subjected to cyclic occlusal forces in a wet acidic environment for 24 h followed by static aqueous immersion for 6 d. The amount of metal ions released was measured using inductively coupled plasma mass spectrometry. Microscopic evaluations were performed pre- and postimmersion under scanning electron microscope (SEM) equipped with energy-dispersive spectroscopy X-ray for corrosion assessment at the interface and wear particle characterization. All platform-switched groups showed less metal ion release compared with their platform-matched counterparts within each abutment material group ( P < 0.001). Implants connected to platform-matched cobalt-chrome abutments demonstrated the highest total mean metal ion release (218 ppb), while the least total mean ion release (11 ppb) was observed in the implants connected to platform-switched titanium abutments ( P ≤ 0.001). Titanium was released from all test groups, with its highest mean release (108 ppb) observed in the implants connected to platform-matched gold abutments ( P < 0.001). SEM images showed surface tribocorrosion features such as pitting and bands of fretting scars. Wear particles were mostly titanium, ranging from submicron to 48 µm in length. The platform-matched groups demonstrated a higher amount of metal ion release and more surface damage. These findings highlight the positive effect of the platform-switching concept in the reduction of tribocorrosion products released from dental implants, which consequently may minimize the adverse tissue reactions that lead to peri-implant bone loss. … (more)
- Is Part Of:
- Journal of dental research. Volume 97:Number 9(2018)
- Journal:
- Journal of dental research
- Issue:
- Volume 97:Number 9(2018)
- Issue Display:
- Volume 97, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 97
- Issue:
- 9
- Issue Sort Value:
- 2018-0097-0009-0000
- Page Start:
- 995
- Page End:
- 1002
- Publication Date:
- 2018-08
- Subjects:
- dental implants -- peri-implantitis -- alveolar bone loss -- titanium -- metal ions -- metal nanoparticles
Dentistry -- Periodicals
Dentistry -- Social aspects -- Periodicals
Dentistry -- Periodicals
Research -- Periodicals
617.6005 - Journal URLs:
- http://jdr.sagepub.com/ ↗
http://www.sagepublications.com/ ↗
http://www.dentalresearch.org/Publications/JournalDentalRsrch/default.htm ↗ - DOI:
- 10.1177/0022034518765751 ↗
- Languages:
- English
- ISSNs:
- 0022-0345
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8521.xml