Comparison of different schedules of nocturnal home blood pressure measurement using an information/communication technology‐based device in hypertensive patients. Issue 11 (23rd October 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of different schedules of nocturnal home blood pressure measurement using an information/communication technology‐based device in hypertensive patients. Issue 11 (23rd October 2018)
- Main Title:
- Comparison of different schedules of nocturnal home blood pressure measurement using an information/communication technology‐based device in hypertensive patients
- Authors:
- Fujiwara, Takeshi
Nishizawa, Masafumi
Hoshide, Satoshi
Kanegae, Hiroshi
Kario, Kazuomi - Abstract:
- Abstract : The objective of this study was to test our hypothesis that nocturnal home blood pressure (BP) measurement adapted to the chosen bedtime of participants (measurement at 2, 3, and 4 hour after the chosen bedtime) would be more reliable than measurement at fixed time points (2:00, 3:00, and 4:00 am ). Forty‐eight hypertensives were randomized to two groups undergoing two seven‐night measurement phases in a crossover manner and were asked to measure nocturnal home BP for 14 consecutive nights using a validated automatic information/communication technology‐based device. The intraclass correlation coefficients (ICCs) of systolic BP (SBP) obtained by a single measurement per night over two nights showed lower agreement than those of systolic BP obtained by multiple measurements based on a participant‐specified bedtime (0.539‐0.625 vs 0.675‐0.768) and multiple measurements at fixed times (0.468‐0.505 vs 0.661‐0.790). The ICCs obtained using specific bedtime‐based time points and those obtained using fixed time points showed major agreement when SBP was obtained by multiple measurements. The standard errors of measurement for SBP were similar between the bedtime‐based measurement phase (1.4‐1.7 mm Hg) and the fixed‐time measurement phase (1.2‐1.6 mm Hg). Neither a fixed bias nor a proportional bias was observed between the SBP values measured by the specific bedtime‐based time points and those measured by the fixed‐time measurement phase. In conclusion, the reliabilityAbstract : The objective of this study was to test our hypothesis that nocturnal home blood pressure (BP) measurement adapted to the chosen bedtime of participants (measurement at 2, 3, and 4 hour after the chosen bedtime) would be more reliable than measurement at fixed time points (2:00, 3:00, and 4:00 am ). Forty‐eight hypertensives were randomized to two groups undergoing two seven‐night measurement phases in a crossover manner and were asked to measure nocturnal home BP for 14 consecutive nights using a validated automatic information/communication technology‐based device. The intraclass correlation coefficients (ICCs) of systolic BP (SBP) obtained by a single measurement per night over two nights showed lower agreement than those of systolic BP obtained by multiple measurements based on a participant‐specified bedtime (0.539‐0.625 vs 0.675‐0.768) and multiple measurements at fixed times (0.468‐0.505 vs 0.661‐0.790). The ICCs obtained using specific bedtime‐based time points and those obtained using fixed time points showed major agreement when SBP was obtained by multiple measurements. The standard errors of measurement for SBP were similar between the bedtime‐based measurement phase (1.4‐1.7 mm Hg) and the fixed‐time measurement phase (1.2‐1.6 mm Hg). Neither a fixed bias nor a proportional bias was observed between the SBP values measured by the specific bedtime‐based time points and those measured by the fixed‐time measurement phase. In conclusion, the reliability of nocturnal home BP measurement appeared to be similar between nocturnal home BP adapted to the chosen bedtime of participants and that measured at fixed time points. … (more)
- Is Part Of:
- Journal of clinical hypertension. Volume 20:Issue 11(2018)
- Journal:
- Journal of clinical hypertension
- Issue:
- Volume 20:Issue 11(2018)
- Issue Display:
- Volume 20, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 20
- Issue:
- 11
- Issue Sort Value:
- 2018-0020-0011-0000
- Page Start:
- 1633
- Page End:
- 1641
- Publication Date:
- 2018-10-23
- Subjects:
- blood pressure -- communication technology‐based device -- information -- nocturnal home blood pressure -- reliability
Hypertension -- Periodicals
616.132 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-7176 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/jch ↗ - DOI:
- 10.1111/jch.13407 ↗
- Languages:
- English
- ISSNs:
- 1524-6175
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.484100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8515.xml