3rd Generation Alumina-on-Alumina in Modular Hip Prosthesis: 13 to 18 Years Follow-up Results. Issue 1 (January 2017)
- Record Type:
- Journal Article
- Title:
- 3rd Generation Alumina-on-Alumina in Modular Hip Prosthesis: 13 to 18 Years Follow-up Results. Issue 1 (January 2017)
- Main Title:
- 3rd Generation Alumina-on-Alumina in Modular Hip Prosthesis: 13 to 18 Years Follow-up Results
- Authors:
- Toni, Aldo
Giardina, Federico
Guerra, Giovanni
Sudanese, Alessandra
Montalti, Maurizio
Stea, Susanna
Bordini, Barbara - Abstract:
- Introduction: Ceramic-on-ceramic (CoC) couplings are alternative bearings surfaces that have been reported to reduce osteolysis, wear debris and aseptic loosening compared to the use of polyethylene. Early experiences with ceramics had poor results, but they have led to many improvements in the manufacture and design of subsequent implants. Methods: We analysed medical files of 300 CoC total hip arthroplasty (THA) with a modular neck performed during period 1995-2000 by a single surgeon for a minimum follow-up of 13 years, evaluating clinical and radiological outcome. Results: The mean clinical Merle d'Aubigne and Postel hip score at the final follow-up is 17.4, against a pre-operative value of 11.4. Overall survivorship with an endpoint of revision is 93.2% (95% CI, 89.0%-97.3%) at 15 years, while considering only prosthesis failures related to aseptic loosening and ceramic breakage, survival rate at 15 years is 97.2% (95% CI, 94.8%-100%). We observed complications that led to revision surgery in 11 patients (4%) (periprosthetic fractures, liner ruptures, septic loosening of the implant, aseptic loosening of the cup, aseptic loosening of the stem). The occurrence of squeaking is low (1.6%, 4 cases) and we analysed the characteristics of these patients. Discussion: Our study shows an excellent long term survivorship of third generation alumina CoC THA. We reiterate the importance to have a stable implant to maximise the advantage of ceramic and to avoid complications.
- Is Part Of:
- Hip international. Volume 27:Issue 1(2017)
- Journal:
- Hip international
- Issue:
- Volume 27:Issue 1(2017)
- Issue Display:
- Volume 27, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 27
- Issue:
- 1
- Issue Sort Value:
- 2017-0027-0001-0000
- Page Start:
- 8
- Page End:
- 13
- Publication Date:
- 2017-01
- Subjects:
- Alumina ceramic -- Ceramic-on-ceramic bearing -- Long-term follow-up -- Total hip replacement
Hip joint -- Pathophysiology -- Periodicals
Hip joint -- Diseases -- Periodicals
Hip joint -- Surgery -- Periodicals
617.581005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/home/hpi ↗ - DOI:
- 10.5301/hipint.5000429 ↗
- Languages:
- English
- ISSNs:
- 1120-7000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8507.xml