Comparison of simultaneous multi-slice readout-segmented EPI and conventional single-shot EPI for diffusion tensor imaging of the ulnar nerve. Issue 10 (October 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of simultaneous multi-slice readout-segmented EPI and conventional single-shot EPI for diffusion tensor imaging of the ulnar nerve. Issue 10 (October 2018)
- Main Title:
- Comparison of simultaneous multi-slice readout-segmented EPI and conventional single-shot EPI for diffusion tensor imaging of the ulnar nerve
- Authors:
- Ho, Michael
Becker, Anton
Ulbrich, Erika
Manoliu, Andrei
Kuhn, Félix P.
Eberhard, Matthias
Filli, Lukas - Abstract:
- Abstract: Purpose: To compare conventional single-shot echo planar imaging (ss-EPI) and simultaneous multi-slice (SMS) readout-segmented EPI (rs-EPI) for magnetic resonance diffusion tensor imaging (DTI) of the ulnar nerve. Materials and methods: This study was approved by the local ethics committee. Ten healthy volunteers (mean age 30.4 ± 4.01 years; range 25–36 years) underwent 3T DTI of the ulnar nerve at the level of the cubital tunnel. DTI was performed based on ss-EPI as well as SMS rs-EPI sequences. Signal-to-noise ratio (SNR), image quality, and DTI parameters in the ulnar nerve (fractional anisotropy, FA; mean diffusivity, MD) were compared between the two sequences by two independent radiologists. Results: Acquisition time was 5:12 min for ss-EPI and 5:18 min for SMS rs-EPI. Between the two sequences, no significant differences were found for derived DTI measures FA (p = 0.11) and MD values (p = 0.93). Compared to conventional ss-EPI, SMS rs-EPI yielded significantly less ghosting artifacts (p = 0.04) but inferior nerve depiction (p = 0.001) and worse overall image quality (p = 0.008). Conclusion: SMS rs-EPI is not advantageous over ss-EPI in DTI of the ulnar nerve at the level of the cubital tunnel.
- Is Part Of:
- Heliyon. Volume 4:Issue 10(2018)
- Journal:
- Heliyon
- Issue:
- Volume 4:Issue 10(2018)
- Issue Display:
- Volume 4, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 4
- Issue:
- 10
- Issue Sort Value:
- 2018-0004-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-10
- Subjects:
- Medical imaging -- Neuroscience -- Neurology
Research -- Periodicals
Medical sciences -- Periodicals
Natural history -- Periodicals
Social sciences -- Periodicals
Earth sciences -- Periodicals
Physical sciences -- Periodicals
507.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/24058440/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.heliyon.2018.e00853 ↗
- Languages:
- English
- ISSNs:
- 2405-8440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8484.xml