An empirical model for calculation of the collimator contamination dose in therapeutic proton beams. (27th January 2016)
- Record Type:
- Journal Article
- Title:
- An empirical model for calculation of the collimator contamination dose in therapeutic proton beams. (27th January 2016)
- Main Title:
- An empirical model for calculation of the collimator contamination dose in therapeutic proton beams
- Authors:
- Vidal, M
De Marzi, L
Szymanowski, H
Guinement, L
Nauraye, C
Hierso, E
Freud, N
Ferrand, R
François, P
Sarrut, D - Abstract:
- Abstract: Collimators are used as lateral beam shaping devices in proton therapy with passive scattering beam lines. The dose contamination due to collimator scattering can be as high as 10% of the maximum dose and influences calculation of the output factor or monitor units (MU). To date, commercial treatment planning systems generally use a zero-thickness collimator approximation ignoring edge scattering in the aperture collimator and few analytical models have been proposed to take scattering effects into account, mainly limited to the inner collimator face component. The aim of this study was to characterize and model aperture contamination by means of a fast and accurate analytical model. The entrance face collimator scatter distribution was modeled as a 3D secondary dose source. Predicted dose contaminations were compared to measurements and Monte Carlo simulations. Measurements were performed on two different proton beam lines (a fixed horizontal beam line and a gantry beam line) with divergent apertures and for several field sizes and energies. Discrepancies between analytical algorithm dose prediction and measurements were decreased from 10% to 2% using the proposed model. Gamma-index (2%/1 mm) was respected for more than 90% of pixels. The proposed analytical algorithm increases the accuracy of analytical dose calculations with reasonable computation times.
- Is Part Of:
- Physics in medicine & biology. Volume 61:Number 4(2016:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 61:Number 4(2016:Feb.)
- Issue Display:
- Volume 61, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 61
- Issue:
- 4
- Issue Sort Value:
- 2016-0061-0004-0000
- Page Start:
- 1532
- Page End:
- 1545
- Publication Date:
- 2016-01-27
- Subjects:
- proton therapy -- collimator scatter -- dose calculation
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/61/4/1532 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8472.xml