Novel crystal timing calibration method based on total variation. (25th October 2016)
- Record Type:
- Journal Article
- Title:
- Novel crystal timing calibration method based on total variation. (25th October 2016)
- Main Title:
- Novel crystal timing calibration method based on total variation
- Authors:
- Yu, Xingjian
Isobe, Takashi
Watanabe, Mitsuo
Liu, Huafeng - Abstract:
- Abstract: A novel crystal timing calibration method based on total variation (TV), abbreviated as 'TV merge', has been developed for a high-resolution positron emission tomography (PET) system. The proposed method was developed for a system with a large number of crystals, it can provide timing calibration at the crystal level. In the proposed method, the timing calibration process was formulated as a linear problem. To robustly optimize the timing resolution, a TV constraint was added to the linear equation. Moreover, to solve the computer memory problem associated with the calculation of the timing calibration factors for systems with a large number of crystals, the merge component was used for obtaining the crystal level timing calibration values. Compared with other conventional methods, the data measured from a standard cylindrical phantom filled with a radioisotope solution was sufficient for performing a high-precision crystal-level timing calibration. In this paper, both simulation and experimental studies were performed to demonstrate the effectiveness and robustness of the TV merge method. We compare the timing resolutions of a 22 Na point source, which was located in the field of view (FOV) of the brain PET system, with various calibration techniques. After implementing the TV merge method, the timing resolution improved from 3.34 ns at full width at half maximum (FWHM) to 2.31 ns FWHM.
- Is Part Of:
- Physics in medicine & biology. Volume 61:Number 22(2016:Nov.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 61:Number 22(2016:Nov.)
- Issue Display:
- Volume 61, Issue 22 (2016)
- Year:
- 2016
- Volume:
- 61
- Issue:
- 22
- Issue Sort Value:
- 2016-0061-0022-0000
- Page Start:
- 7833
- Page End:
- 7847
- Publication Date:
- 2016-10-25
- Subjects:
- PET -- timing calibration -- total variation constraint -- merge component
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/61/22/7833 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8491.xml