Bone density measurements adjacent to acetabular cups in total hip arthroplasty using dual-energy CT: an in vivo reliability and agreement study. (August 2018)
- Record Type:
- Journal Article
- Title:
- Bone density measurements adjacent to acetabular cups in total hip arthroplasty using dual-energy CT: an in vivo reliability and agreement study. (August 2018)
- Main Title:
- Bone density measurements adjacent to acetabular cups in total hip arthroplasty using dual-energy CT: an in vivo reliability and agreement study
- Authors:
- Mussmann, Bo
Andersen, Poul Erik
Torfing, Trine
Overgaard, Søren - Abstract:
- Background: Measuring bone mineral density (BMD) around acetabular prosthetic components with computed tomography (CT) is challenged by the complex anatomy and metal artifacts. Three-dimensional (3D) segmentation is required for the analysis, but it is usually not practically applicable on current CT workstations Purpose: To test the between-scan agreement and reliability of custom segmentation software for BMD measurements adjacent to cemented and uncemented acetabular cups in dual-energy CT (DECT). Material and Methods: Twenty-four male patients with total hip arthroplasty were scanned and rescanned using 130-keV virtual monochromatic DECT images. Hemispherical regions of interest were defined slice-by-slice and BMD was calculated around the acetabular cup using custom segmentation software. Results: In the uncemented cup, the mean BMD was 153 mg/cm 3 with a between-scan difference of 10 mg/cm 3 ( P < 0.0001). In the cemented cup, the mean BMD was 186 mg/cm 3 with a between-scan difference of 6 mg/cm 3 ( P = 0.15). In both uncemented and cemented cups the intraclass correlation coefficient between repeated measurements was >0.95 and narrow Bland–Altman Limits of Agreement. Conclusion: BMD can be measured with high absolute between-scan agreement and good reliability adjacent to acetabular cemented and uncemented cups using DECT and segmentation software.
- Is Part Of:
- Acta radiologica open. Volume 7:Number 9(2018)
- Journal:
- Acta radiologica open
- Issue:
- Volume 7:Number 9(2018)
- Issue Display:
- Volume 7, Issue 9 (2018)
- Year:
- 2018
- Volume:
- 7
- Issue:
- 9
- Issue Sort Value:
- 2018-0007-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08
- Subjects:
- Segmentation -- computed tomography bone density -- dual energy computed tomography -- bone loss -- hip loosening cup
Radiology -- Periodicals
Diagnostic Imaging -- Periodicals
Radiology
Periodicals
616.075705 - Journal URLs:
- http://arr.sagepub.com/ ↗
http://arr.sagepub.com/ ↗
http://www.uk.sagepub.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/2704/ ↗ - DOI:
- 10.1177/2058460118796539 ↗
- Languages:
- English
- ISSNs:
- 2058-4601
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8476.xml