Phosphene perception and pupillary responses to sinusoidal electrostimulation - For an objective measurement of retinal function. (November 2018)
- Record Type:
- Journal Article
- Title:
- Phosphene perception and pupillary responses to sinusoidal electrostimulation - For an objective measurement of retinal function. (November 2018)
- Main Title:
- Phosphene perception and pupillary responses to sinusoidal electrostimulation - For an objective measurement of retinal function
- Authors:
- Kelbsch, Carina
Jalligampala, Archana
Strasser, Torsten
Richter, Paul
Stingl, Katarina
Braun, Christoph
Rathbun, Daniel L.
Zrenner, Eberhart
Wilhelm, Helmut
Wilhelm, Barbara
Peters, Tobias
Stingl, Krunoslav - Abstract:
- Abstract: The purpose was to evaluate retinal function by measuring pupillary responses to sinusoidal transcorneal electrostimulation in healthy young human subjects. This work also translates data from analogous in vitro experiments and connects it to the pupillary responses obtained in human experiments. 14 healthy human subjects participated (4 males, 10 females); for the in vitro experiments, two male healthy mouse retinas (adult wild-type C57B/6J) were used. Pupillary responses to sinusoidal transcorneal electrostimulation of varying stimulus carrier frequencies (10, 20 Hz; envelope frequency constantly kept at 1.2 Hz) and intensities (10, 20, 50 μA) were recorded and compared with those obtained with light stimulation (1.2 Hz sinusoidal blue, red light). A strong correlation between the sinusoidal stimulation (electrical as well as light) and the pupillary sinusoidal response was found. The difference between the lag of electrical and light stimulation allowed the estimation of an intensity threshold for pupillary responses to transcorneal electrostimulation (mean ± SD: 30 ± 10 μA (10 Hz); 38 ± 10 μA (20 Hz)). A comparison between the results of the two stimulation frequencies showed a not statistically significant smaller lag for 10 Hz (10 Hz: 633 ± 90 ms; 20 Hz: 725 ± 178 ms; 50 μA intensity). Analogous in vitro experiments on murine retinas indicated a selective stimulation of photoreceptors and bipolar cells (lower frequencies) and retinal ganglion cells (higherAbstract: The purpose was to evaluate retinal function by measuring pupillary responses to sinusoidal transcorneal electrostimulation in healthy young human subjects. This work also translates data from analogous in vitro experiments and connects it to the pupillary responses obtained in human experiments. 14 healthy human subjects participated (4 males, 10 females); for the in vitro experiments, two male healthy mouse retinas (adult wild-type C57B/6J) were used. Pupillary responses to sinusoidal transcorneal electrostimulation of varying stimulus carrier frequencies (10, 20 Hz; envelope frequency constantly kept at 1.2 Hz) and intensities (10, 20, 50 μA) were recorded and compared with those obtained with light stimulation (1.2 Hz sinusoidal blue, red light). A strong correlation between the sinusoidal stimulation (electrical as well as light) and the pupillary sinusoidal response was found. The difference between the lag of electrical and light stimulation allowed the estimation of an intensity threshold for pupillary responses to transcorneal electrostimulation (mean ± SD: 30 ± 10 μA (10 Hz); 38 ± 10 μA (20 Hz)). A comparison between the results of the two stimulation frequencies showed a not statistically significant smaller lag for 10 Hz (10 Hz: 633 ± 90 ms; 20 Hz: 725 ± 178 ms; 50 μA intensity). Analogous in vitro experiments on murine retinas indicated a selective stimulation of photoreceptors and bipolar cells (lower frequencies) and retinal ganglion cells (higher frequencies) and lower stimulation thresholds for the retinal network with sinusoidal compared to pulsatile stimulation – emphasizing that sinusoidal waveforms are well-suited to our purposes. We demonstrate that pupillary responses to sinusoidal transcorneal electrostimulation are measurable as an objective marker in healthy young subjects, even at very low stimulus intensities. By using this unique approach, we unveil the potential for an estimation of the individual intensity threshold and a selective activation of different retinal cell types in humans by varying the stimulation frequency. This technique may have broad clinical utility as well as specific relevance in the monitoring of patients with hereditary retinal disorders, especially as implemented in study protocols for novel therapies, e.g. retinal prostheses or gene therapies. Highlights: Functional evaluation of the retina in humans based on pupillary responses. New paradigm for transcorneal sinusoidal electrical stimulation. Method for an easy estimation of individual thresholds for pupillary responses. Possibility for a selective activation of different retinal cell types. Verification of sinusoidal stimulation in animal in vitro model. … (more)
- Is Part Of:
- Experimental eye research. Volume 176(2018)
- Journal:
- Experimental eye research
- Issue:
- Volume 176(2018)
- Issue Display:
- Volume 176, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 176
- Issue:
- 2018
- Issue Sort Value:
- 2018-0176-2018-0000
- Page Start:
- 210
- Page End:
- 218
- Publication Date:
- 2018-11
- Subjects:
- Pupil -- Sinusoidal electrical stimulation -- Phosphenes -- Micro-electrode-array
Ophthalmology -- Periodicals
Eye -- Periodicals
Œil -- Périodiques
Ophthalmology
Periodicals
Electronic journals
612.8405 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00144835 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0014-4835;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.exer.2018.07.010 ↗
- Languages:
- English
- ISSNs:
- 0014-4835
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3839.150000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8457.xml