Contrast Enhanced Three Dimensional Ultrasound for Intraluminal Thrombus Assessment in Abdominal Aortic Aneurysms. (November 2018)
- Record Type:
- Journal Article
- Title:
- Contrast Enhanced Three Dimensional Ultrasound for Intraluminal Thrombus Assessment in Abdominal Aortic Aneurysms. (November 2018)
- Main Title:
- Contrast Enhanced Three Dimensional Ultrasound for Intraluminal Thrombus Assessment in Abdominal Aortic Aneurysms
- Authors:
- Ghulam, Qasam M.
Bredahl, Kim
Sandholt, Benjamin
Taudorf, Mikkel
Lönn, Lars
Rouet, Laurence
Sillesen, Henrik
Eiberg, Jonas P. - Abstract:
- Abstract : Objectives: The impact of intraluminal thrombus (ILT) on abdominal aortic aneurysm (AAA) progression can be investigated non-invasively by three dimensional contrast enhanced ultrasound (3D-CEUS). The aim was to validate 3D-CEUS ILT volume and thickness measurements against computed tomography angiography (CTA), and to determine inter- and intra-operator reproducibility. Methods: The design was for a planned comparison of 3D-CEUS and CTA and of repeated 3D-CEUS measurements in a blinded set up. Consecutive patients with asymptomatic AAA ( n = 137, maximum diameter 30–55 mm) from a single centre were consecutively assessed by CTA and 3D-CEUS in a blinded setup. After exclusion of failed CTA ( n = 2) and inconclusive 3D-CEUS ( n = 8), 127 3D-CEUS/CTA pairs were analysed by Bland–Altman plots. 3D-CEUS inter- and intra-operator reproducibility were determined in a subgroup ( n = 30) measured twice by two blinded investigators. Results: In 24 of 127 (19%) patients, no ILT was found on 3D-CEUS. Intraluminal thrombus absence was confirmed by 3D-CTA analysis in all but two cases. Mean ILT volume difference between 3D-CEUS and CTA was 2.2 mL (5% of mean volume) and range of variability (ROV) amounted to ± 10.2 mL. Mean ILT thickness difference was 0.6 mm with a ROV of ± 4.6 mm 3D-CEUS inter-operator variations of ILT volume and thickness measurements were low (ROV ± 8.8 mL and ±2.9 mm, respectively). The corresponding intra-operator ROVs were ±7.5 mL and ±3.3 mm,Abstract : Objectives: The impact of intraluminal thrombus (ILT) on abdominal aortic aneurysm (AAA) progression can be investigated non-invasively by three dimensional contrast enhanced ultrasound (3D-CEUS). The aim was to validate 3D-CEUS ILT volume and thickness measurements against computed tomography angiography (CTA), and to determine inter- and intra-operator reproducibility. Methods: The design was for a planned comparison of 3D-CEUS and CTA and of repeated 3D-CEUS measurements in a blinded set up. Consecutive patients with asymptomatic AAA ( n = 137, maximum diameter 30–55 mm) from a single centre were consecutively assessed by CTA and 3D-CEUS in a blinded setup. After exclusion of failed CTA ( n = 2) and inconclusive 3D-CEUS ( n = 8), 127 3D-CEUS/CTA pairs were analysed by Bland–Altman plots. 3D-CEUS inter- and intra-operator reproducibility were determined in a subgroup ( n = 30) measured twice by two blinded investigators. Results: In 24 of 127 (19%) patients, no ILT was found on 3D-CEUS. Intraluminal thrombus absence was confirmed by 3D-CTA analysis in all but two cases. Mean ILT volume difference between 3D-CEUS and CTA was 2.2 mL (5% of mean volume) and range of variability (ROV) amounted to ± 10.2 mL. Mean ILT thickness difference was 0.6 mm with a ROV of ± 4.6 mm 3D-CEUS inter-operator variations of ILT volume and thickness measurements were low (ROV ± 8.8 mL and ±2.9 mm, respectively). The corresponding intra-operator ROVs were ±7.5 mL and ±3.3 mm, respectively. Conclusions: 3D-CEUS demonstrated good reproducibility and a good agreement with CTA when estimating ILT volume and maximum thickness in AAA patients. It is a promising research tool to investigate potential interactions between ILT, AAA growth, and rupture. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 56:Number 5(2018)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 56:Number 5(2018)
- Issue Display:
- Volume 56, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 5
- Issue Sort Value:
- 2018-0056-0005-0000
- Page Start:
- 673
- Page End:
- 680
- Publication Date:
- 2018-11
- Subjects:
- Abdominal aortic aneurysm -- Three dimensional contrast enhanced ultrasound -- Intraluminal thrombus volume -- Intraluminal thrombus thickness
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2018.07.029 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8462.xml