Higgins, Gary - Abstract:
- Graphical abstract: Highlights: The proposed input selection method can efficiently determine the input parameters. The model performance improves by considering all relevant key aspects. Prediction performance deteriorates quite drastically after a certain time span. The proposed model provides good prediction performance till 28 days ahead. Abstract: Indoor environmental parameters have significant influence on commercial building energy consumption and indoor thermal comfort. Prediction of these parameters, especially that of indoor air temperature, along with continuous monitoring and control of real world parameters can aid in the management of energy consumption and thermal comfort levels in existing buildings. An accurate indoor temperature prediction model assists in achieving an effective energy management strategy such as resetting air temperature set-points in commercial buildings. This study examines the real indoor environmental data for multiple adjacent zones in a commercial building in the context of thermal comfort and identifies the possibility of resetting air temperature set-point without compromising the occupant comfort level. Also, the value of predicting the indoor temperature accurately in such a building is established through this case study. This study presents a nonlinear autoregressive network with exogenous inputs-based system identification method to predict indoor temperature. During model development efforts have been paid to optimize theGraphical abstract: Highlights: The proposed input selection method can efficiently determine the input parameters. The model performance improves by considering all relevant key aspects. Prediction performance deteriorates quite drastically after a certain time span. The proposed model provides good prediction performance till 28 days ahead. Abstract: Indoor environmental parameters have significant influence on commercial building energy consumption and indoor thermal comfort. Prediction of these parameters, especially that of indoor air temperature, along with continuous monitoring and control of real world parameters can aid in the management of energy consumption and thermal comfort levels in existing buildings. An accurate indoor temperature prediction model assists in achieving an effective energy management strategy such as resetting air temperature set-points in commercial buildings. This study examines the real indoor environmental data for multiple adjacent zones in a commercial building in the context of thermal comfort and identifies the possibility of resetting air temperature set-point without compromising the occupant comfort level. Also, the value of predicting the indoor temperature accurately in such a building is established through this case study. This study presents a nonlinear autoregressive network with exogenous inputs-based system identification method to predict indoor temperature. During model development efforts have been paid to optimize the performance of the model in terms of complexity, prediction results and ease of application to a real system. The performance of single-zone and multi-zone prediction models is evaluated using different combinations and sizes of training data-sets. This study confirms that evaluating the performance of the model in the context of major contributing aspects such as optimal input parameters and network size, optimum size of training data, etc. offers optimized model performance. Thus, when the developed model is used for long-term prediction, it provides better prediction performance for an extended time span compared to existing studies. Therefore, it is anticipated that implementation of this long-term prediction model will offer greater energy savings and improved indoor environmental conditions through optimizing the set-point temperatures. … (more)
- Is Part Of:
- Applied energy. Volume 231(2018)
- Journal:
- Applied energy
- Issue:
- Volume 231(2018)
- Issue Display:
- Volume 231, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 231
- Issue:
- 2018
- Issue Sort Value:
- 2018-0231-2018-0000
- Page Start:
- 29
- Page End:
- 53
- Publication Date:
- 2018-12-01
- Subjects:
- Prediction model -- Indoor temperature -- NARX -- Performance improvement -- Single-zone and multi-zone
Power (Mechanics) -- Periodicals
Energy conservation -- Periodicals
Energy conversion -- Periodicals
621.042 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03062619 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apenergy.2018.09.052 ↗
- Languages:
- English
- ISSNs:
- 0306-2619
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1572.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8449.xml