Clinical experience with wearable cardioverter defibrillators at a tertiary electrophysiology program. Issue 11 (29th September 2018)
- Record Type:
- Journal Article
- Title:
- Clinical experience with wearable cardioverter defibrillators at a tertiary electrophysiology program. Issue 11 (29th September 2018)
- Main Title:
- Clinical experience with wearable cardioverter defibrillators at a tertiary electrophysiology program
- Authors:
- Bossory, Laurie
Schubert, Scott
Afzal, Muhammad R.
Weiss, Raul
Tyler, Jaret
Kalbfleisch, Steven
Augostini, Ralph
Hummel, John
Okabe, Toshimasa
Daoud, Emile G.
Houmsse, Mahmoud - Abstract:
- Abstract: Background: A wearable cardioverter defibrillator (WCD) is an alternative for patients who are not immediate candidates for an implantable cardioverter defibrillator (ICD). Methods: Retrospective analysis of 242 patients prescribed a WCD from January 2014 through March 2015 with 1‐year follow‐up. Results: A WCD was prescribed to 242 patients during the 15‐month period. Forty‐one patients were excluded due to lack of complete follow‐up. The remaining 201 patients received a WCD for primary or secondary prevention of SCD. Seventy‐nine percent of WCDs were prescribed by nonelectrophysiologists. Underlying etiologies for the WCD prescription included: 38% nonischemic cardiomyopathy, 25% recent myocardial infarction, 16% newly diagnosed ischemic cardiomyopathy, 12% documented ventricular arrhythmia, 6% ICD lead extraction, and 3% had high risk conditions for sudden cardiac death. During 1‐year follow‐up, 96 patients (48%) received an ICD and five patients (2.5%) received appropriate shocks and one patient (0.5 %) received an inappropriate shock. Other 105 (52%) patients subsequently did not require an ICD due to either improvement in ejection fraction, refusal of ICD therapy, or death. Conclusions: About half of patients prescribed a WCD subsequently receive an ICD and the rate of appropriate shock therapy from the WCD is 2.5%.
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 41:Issue 11(2018)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 41:Issue 11(2018)
- Issue Display:
- Volume 41, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 11
- Issue Sort Value:
- 2018-0041-0011-0000
- Page Start:
- 1491
- Page End:
- 1494
- Publication Date:
- 2018-09-29
- Subjects:
- cardiomyopathy -- sudden cardiac arrest -- wearable cardioverter defibrillator
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13491 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8440.xml