Baxter elastomeric pumps: Weighing as an alternative to visual inspection. (April 2018)
- Record Type:
- Journal Article
- Title:
- Baxter elastomeric pumps: Weighing as an alternative to visual inspection. (April 2018)
- Main Title:
- Baxter elastomeric pumps: Weighing as an alternative to visual inspection
- Authors:
- Cusano, Ellen L
Ali, Raafi
Sawyer, Michael B
Chambers, Carole R
Tang, Patricia A - Abstract:
- Purpose: Elastomeric pumps are used to administer 46-hour infusions of 5-fluorouracil (5FU). Baxter suggests patients visually monitor their pumps to ensure that infusions are proceeding correctly. This can be confusing and lead to concerns about under- or over-dosing. Baxter has not considered weighing pumps as a validated method for monitoring. This study aims to validate weighing as a more accurate method for patients and healthcare professionals, and describe real life Baxter Infusor™ variability. Methods: Patients who had been started on a 46-hour 5FU infusion returned to the clinic approximately 24 h after starting treatment. The pump was weighed on a StarFrit kitchen scale, and date, time, and weights recorded. Patients were asked if they had a preference for weighing or visually inspecting their pump. Results: Pumps ( n = 103) were weighed between 17.25 and 27.5 h after connection. The average weight of a pump was 189 g. Of 103 pumps weighed, 99 weighed less than expected, corresponding to average flow rates of 5.69 mL/h over the elapsed time. The expected flow rate is 5 mL/h with 10% variability. Average flow rates within the 17.25- to 27.5-hour window were 4.561 mL/h, which is 8.78% slower than expected, but within the 10% known variability. Forty-seven percent of patients didn't have a preference for either method, but for those who did have a preference, more than twice as many preferred weighing. Conclusion: With proper education, weighing Baxter Infusors atPurpose: Elastomeric pumps are used to administer 46-hour infusions of 5-fluorouracil (5FU). Baxter suggests patients visually monitor their pumps to ensure that infusions are proceeding correctly. This can be confusing and lead to concerns about under- or over-dosing. Baxter has not considered weighing pumps as a validated method for monitoring. This study aims to validate weighing as a more accurate method for patients and healthcare professionals, and describe real life Baxter Infusor™ variability. Methods: Patients who had been started on a 46-hour 5FU infusion returned to the clinic approximately 24 h after starting treatment. The pump was weighed on a StarFrit kitchen scale, and date, time, and weights recorded. Patients were asked if they had a preference for weighing or visually inspecting their pump. Results: Pumps ( n = 103) were weighed between 17.25 and 27.5 h after connection. The average weight of a pump was 189 g. Of 103 pumps weighed, 99 weighed less than expected, corresponding to average flow rates of 5.69 mL/h over the elapsed time. The expected flow rate is 5 mL/h with 10% variability. Average flow rates within the 17.25- to 27.5-hour window were 4.561 mL/h, which is 8.78% slower than expected, but within the 10% known variability. Forty-seven percent of patients didn't have a preference for either method, but for those who did have a preference, more than twice as many preferred weighing. Conclusion: With proper education, weighing Baxter Infusors at home with kitchen scales can be an accepted and objective alternative to the current recommendation of visual inspection. … (more)
- Is Part Of:
- Journal of oncology pharmacy practice. Volume 24:Number 3(2018)
- Journal:
- Journal of oncology pharmacy practice
- Issue:
- Volume 24:Number 3(2018)
- Issue Display:
- Volume 24, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 24
- Issue:
- 3
- Issue Sort Value:
- 2018-0024-0003-0000
- Page Start:
- 163
- Page End:
- 169
- Publication Date:
- 2018-04
- Subjects:
- Baxter infusor -- weight -- chemotherapy
Cancer -- Chemotherapy -- Periodicals
Clinical pharmacology -- Periodicals
616.994061 - Journal URLs:
- http://opp.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1078155216687153 ↗
- Languages:
- English
- ISSNs:
- 1078-1552
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8439.xml