Experimental investigation of irregular motion impact on 4D PET-based particle therapy monitoring. (6th January 2016)
- Record Type:
- Journal Article
- Title:
- Experimental investigation of irregular motion impact on 4D PET-based particle therapy monitoring. (6th January 2016)
- Main Title:
- Experimental investigation of irregular motion impact on 4D PET-based particle therapy monitoring
- Authors:
- Tian, Y
Stützer, K
Enghardt, W
Priegnitz, M
Helmbrecht, S
Bert, C
Fiedler, F - Abstract:
- Abstract: Particle therapy positron emission tomography (PT-PET) is an in vivo and non-invasive imaging technique to monitor treatment delivery in particle therapy. The inevitable patient respiratory motion during irradiation causes artefacts and inaccurate activity distribution in PET images. Four-dimensional (4D) maximum likelihood expectation maximisation (4D MLEM) allows for a compensation of these effects, but has up to now been restricted to regular motion for PT-PET investigations. However, intra-fractional motion during treatment might differ from that during acquisition of the 4D-planning CT (e.g. amplitude variation, baseline drift) and therefore might induce inaccurate 4D PET reconstruction results. This study investigates the impact of different irregular analytical one-dimensional (1D) motion patterns on PT-PET imaging by means of experiments with a radioactive source and irradiated moving phantoms. Three sorting methods, namely phase sorting, equal amplitude sorting and event-based amplitude sorting, were applied to manage the PET list-mode data. The influence of these sorting methods on the motion compensating algorithm has been analysed. The event-based amplitude sorting showed a superior performance and it is applicable for irregular motions with ⩽4 mm amplitude elongation and drift. For motion with 10 mm baseline drift, the normalised root mean square error was as high as 10.5% and a 10 mm range deviation was observed.
- Is Part Of:
- Physics in medicine & biology. Volume 61:Number 2(2016:Jan.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 61:Number 2(2016:Jan.)
- Issue Display:
- Volume 61, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 61
- Issue:
- 2
- Issue Sort Value:
- 2016-0061-0002-0000
- Page Start:
- N20
- Page End:
- N34
- Publication Date:
- 2016-01-06
- Subjects:
- irregular target motion -- 4D PET -- particle therapy -- dose monitoring
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/61/2/N20 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8419.xml