A graphite calorimeter for absolute measurements of absorbed dose to water: application in medium-energy x-ray filtered beams. (3rd February 2016)
- Record Type:
- Journal Article
- Title:
- A graphite calorimeter for absolute measurements of absorbed dose to water: application in medium-energy x-ray filtered beams. (3rd February 2016)
- Main Title:
- A graphite calorimeter for absolute measurements of absorbed dose to water: application in medium-energy x-ray filtered beams
- Authors:
- Pinto, M
Pimpinella, M
Quini, M
D'Arienzo, M
Astefanoaei, I
Loreti, S
Guerra, A S - Abstract:
- Abstract: The Italian National Institute of Ionizing Radiation Metrology (ENEA-INMRI) has designed and built a graphite calorimeter that, in a water phantom, has allowed the determination of the absorbed dose to water in medium-energy x-rays with generating voltages from 180 to 250 kV. The new standard is a miniaturized three-bodies calorimeter, with a disc-shaped core of 21 mm diameter and 2 mm thickness weighing 1.134 g, sealed in a PMMA waterproof envelope with air-evacuated gaps. The measured absorbed dose to graphite is converted into absorbed dose to water by means of an energy-dependent conversion factor obtained from Monte Carlo simulations. Heat-transfer correction factors were determined by FEM calculations. At a source-to-detector distance of 100 cm, a depth in water of 2 g cm −2, and at a dose rate of about 0.15 Gy min −1, results of calorimetric measurements of absorbed dose to water, D w, were compared to experimental determinations, D wK, obtained via an ionization chamber calibrated in terms of air kerma, according to established dosimetry protocols. The combined standard uncertainty of D w and D wK were estimated as 1.9% and 1.7%, respectively. The two absorbed dose to water determinations were in agreement within 1%, well below the stated measurement uncertainties. Advancements are in progress to extend the measurement capability of the new in-water-phantom graphite calorimeter to other filtered medium-energy x-ray qualities and to reduce the D wAbstract: The Italian National Institute of Ionizing Radiation Metrology (ENEA-INMRI) has designed and built a graphite calorimeter that, in a water phantom, has allowed the determination of the absorbed dose to water in medium-energy x-rays with generating voltages from 180 to 250 kV. The new standard is a miniaturized three-bodies calorimeter, with a disc-shaped core of 21 mm diameter and 2 mm thickness weighing 1.134 g, sealed in a PMMA waterproof envelope with air-evacuated gaps. The measured absorbed dose to graphite is converted into absorbed dose to water by means of an energy-dependent conversion factor obtained from Monte Carlo simulations. Heat-transfer correction factors were determined by FEM calculations. At a source-to-detector distance of 100 cm, a depth in water of 2 g cm −2, and at a dose rate of about 0.15 Gy min −1, results of calorimetric measurements of absorbed dose to water, D w, were compared to experimental determinations, D wK, obtained via an ionization chamber calibrated in terms of air kerma, according to established dosimetry protocols. The combined standard uncertainty of D w and D wK were estimated as 1.9% and 1.7%, respectively. The two absorbed dose to water determinations were in agreement within 1%, well below the stated measurement uncertainties. Advancements are in progress to extend the measurement capability of the new in-water-phantom graphite calorimeter to other filtered medium-energy x-ray qualities and to reduce the D w uncertainty to around 1%. The new calorimeter represents the first implementation of in-water-phantom graphite calorimetry in the kilovoltage range and, allowing independent determinations of D w, it will contribute to establish a robust system of absorbed dose to water primary standards for medium-energy x-ray beams. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 61:Number 4(2016:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 61:Number 4(2016:Feb.)
- Issue Display:
- Volume 61, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 61
- Issue:
- 4
- Issue Sort Value:
- 2016-0061-0004-0000
- Page Start:
- 1738
- Page End:
- 1764
- Publication Date:
- 2016-02-03
- Subjects:
- graphite calorimetry -- calorimetry -- medium-energy x-rays -- reference dosimetry -- primary standard -- x-ray dosimetry
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/61/4/1738 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8410.xml