Extended ellipse-line-ellipse trajectory for long-object cone-beam imaging with a mounted C-arm system. (8th February 2016)
- Record Type:
- Journal Article
- Title:
- Extended ellipse-line-ellipse trajectory for long-object cone-beam imaging with a mounted C-arm system. (8th February 2016)
- Main Title:
- Extended ellipse-line-ellipse trajectory for long-object cone-beam imaging with a mounted C-arm system
- Authors:
- Yu, Zhicong
Lauritsch, Günter
Dennerlein, Frank
Mao, Yanfei
Hornegger, Joachim
Noo, Frédéric - Abstract:
- Abstract: Recent reports show that three-dimensional cone-beam (CB) imaging with a floor-mounted (or ceiling-mounted) C-arm system has become a valuable tool in interventional radiology. Currently, a circular short scan is used for data acquisition, which inevitably yields CB artifacts and a short coverage in the direction of the patient table. To overcome these two limitations, a more sophisticated data acquisition geometry is needed. This geometry should be complete in terms of Tuy's condition and should allow continuous scanning, while being compatible with the mechanical constraints of mounted C-arm systems. Additionally, the geometry should allow accurate image reconstruction from truncated data. One way to ensure such a feature is to adopt a trajectory that provides full R-line coverage within the field-of-view (FOV). An R-line is any segment of line that connects two points on a source trajectory, and the R-line coverage is the set of points that belong to an R-line. In this work, we propose a novel geometry called the extended ellipse-line-ellipse (ELE) for long-object imaging with a mounted C-arm system. This trajectory is built from modules consisting of two elliptical arcs connected by a line. We demonstrate that the extended ELE can be configured in many ways so that full R-line coverage is guaranteed. Both tight and relaxed parametric settings are presented. All results are supported by extensive mathematical proofs provided in appendices. Our findings make theAbstract: Recent reports show that three-dimensional cone-beam (CB) imaging with a floor-mounted (or ceiling-mounted) C-arm system has become a valuable tool in interventional radiology. Currently, a circular short scan is used for data acquisition, which inevitably yields CB artifacts and a short coverage in the direction of the patient table. To overcome these two limitations, a more sophisticated data acquisition geometry is needed. This geometry should be complete in terms of Tuy's condition and should allow continuous scanning, while being compatible with the mechanical constraints of mounted C-arm systems. Additionally, the geometry should allow accurate image reconstruction from truncated data. One way to ensure such a feature is to adopt a trajectory that provides full R-line coverage within the field-of-view (FOV). An R-line is any segment of line that connects two points on a source trajectory, and the R-line coverage is the set of points that belong to an R-line. In this work, we propose a novel geometry called the extended ellipse-line-ellipse (ELE) for long-object imaging with a mounted C-arm system. This trajectory is built from modules consisting of two elliptical arcs connected by a line. We demonstrate that the extended ELE can be configured in many ways so that full R-line coverage is guaranteed. Both tight and relaxed parametric settings are presented. All results are supported by extensive mathematical proofs provided in appendices. Our findings make the extended ELE trajectory attractive for axially-extended FOV imaging in interventional radiology. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 61:Number 4(2016:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 61:Number 4(2016:Feb.)
- Issue Display:
- Volume 61, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 61
- Issue:
- 4
- Issue Sort Value:
- 2016-0061-0004-0000
- Page Start:
- 1829
- Page End:
- 1851
- Publication Date:
- 2016-02-08
- Subjects:
- R-line -- long-object -- C-arm -- cone-beam -- tomography -- ELE
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/61/4/1829 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8410.xml