Accuracy of actual resected liver volume in anatomical liver resections guided by 3‐dimensional parenchymal staining using fusion indocyanine green fluorescence imaging. Issue 7 (7th October 2018)
- Record Type:
- Journal Article
- Title:
- Accuracy of actual resected liver volume in anatomical liver resections guided by 3‐dimensional parenchymal staining using fusion indocyanine green fluorescence imaging. Issue 7 (7th October 2018)
- Main Title:
- Accuracy of actual resected liver volume in anatomical liver resections guided by 3‐dimensional parenchymal staining using fusion indocyanine green fluorescence imaging
- Authors:
- Yang, Jian
Tao, Hai‐Su
Cai, Wei
Zhu, Wen
Zhao, Dong
Hu, Hao‐Yu
Liu, Jun
Fang, Chi‐Hua - Abstract:
- Abstract : Background: The aim of this study was to assess the accuracy of actual resected liver volume (ARLV) in anatomical liver resections (ALRs) guided by 3‐dimensional parenchymal staining using fusion indocyanine green fluorescence imaging (IGFI). Methods: Patients eligible for hepatic resection were enrolled in the current study from January 2016 to November 2017. All patients underwent surgery planning based on Medical Image Three‐Dimensional Visualization System (MI‐3DVS) before the operation, in which predicted resected liver volumes (PRLVs) were calculated. Under 3‐dimensional guidance by fusion IGFI, ALRs were performed and ARLVs were measured. Simple linear regression, intra‐class correlation coefficient (ICC) and Bland‐Altman analysis were used to evaluate the relationship and agreement between PRLV and ARLV. Results: Of the 27 patients who achieved valid demarcation by fusion IGFI, 12 (44.4%) received hemihepatectomy, while 10 (37.0%) and five (18.5%) underwent sectionectomy and segmentectomy, respectively. The relationship and agreement between PRLV (481.37 ± 189.47 cm³) and ARLV (450.57 ± 205.19 cm³) were then evaluated. The simple regression equation obtained was PRLV = 0.874 × ARLV + 87.75 ( R = 0.946; P = 0.000). Meanwhile, ARLV (ICC = 0.943) achieved an excellent agreement with PRLV ( P < 0.001); 25 of 27 dots were in the range of 95% confidence interval in Bland‐Altman analysis. Conclusions: In the study, these findings validated the consistencyAbstract : Background: The aim of this study was to assess the accuracy of actual resected liver volume (ARLV) in anatomical liver resections (ALRs) guided by 3‐dimensional parenchymal staining using fusion indocyanine green fluorescence imaging (IGFI). Methods: Patients eligible for hepatic resection were enrolled in the current study from January 2016 to November 2017. All patients underwent surgery planning based on Medical Image Three‐Dimensional Visualization System (MI‐3DVS) before the operation, in which predicted resected liver volumes (PRLVs) were calculated. Under 3‐dimensional guidance by fusion IGFI, ALRs were performed and ARLVs were measured. Simple linear regression, intra‐class correlation coefficient (ICC) and Bland‐Altman analysis were used to evaluate the relationship and agreement between PRLV and ARLV. Results: Of the 27 patients who achieved valid demarcation by fusion IGFI, 12 (44.4%) received hemihepatectomy, while 10 (37.0%) and five (18.5%) underwent sectionectomy and segmentectomy, respectively. The relationship and agreement between PRLV (481.37 ± 189.47 cm³) and ARLV (450.57 ± 205.19 cm³) were then evaluated. The simple regression equation obtained was PRLV = 0.874 × ARLV + 87.75 ( R = 0.946; P = 0.000). Meanwhile, ARLV (ICC = 0.943) achieved an excellent agreement with PRLV ( P < 0.001); 25 of 27 dots were in the range of 95% confidence interval in Bland‐Altman analysis. Conclusions: In the study, these findings validated the consistency between PRLV calculated by MI‐3DVS and ARLV guided by fusion IGFI, which proved that IGFI can accurately guide anatomical hepatectomy. Generally, fusion IGFI can provide a valid, feasible and accurate demarcation line, which can confer precision to hepatic resection. … (more)
- Is Part Of:
- Journal of surgical oncology. Volume 118:Issue 7(2018)
- Journal:
- Journal of surgical oncology
- Issue:
- Volume 118:Issue 7(2018)
- Issue Display:
- Volume 118, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 118
- Issue:
- 7
- Issue Sort Value:
- 2018-0118-0007-0000
- Page Start:
- 1081
- Page End:
- 1087
- Publication Date:
- 2018-10-07
- Subjects:
- 3D -- anatomical liver resections (ALRs) -- indocyanine green fluorescence imaging (IGFI)
Cancer -- Surgery -- Periodicals
Neoplasms -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1096-9098 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jso.25258 ↗
- Languages:
- English
- ISSNs:
- 0022-4790
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5067.380000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8395.xml