Roughness and Microhardness of Composites after Different Bleaching Techniques. Issue 4 (October 2015)
- Record Type:
- Journal Article
- Title:
- Roughness and Microhardness of Composites after Different Bleaching Techniques. Issue 4 (October 2015)
- Main Title:
- Roughness and Microhardness of Composites after Different Bleaching Techniques
- Authors:
- Leal, Andreia
Paula, Anabela
Ramalho, Amílcar
Esteves, Miguel
Ferreira, Manuel Marques
Carrilho, Eunice - Abstract:
- Background: The aim of this study was to evaluate the roughness and microhardness of SonicFill™ (Kerr), and compare it with Filtek™ Supreme XTE (3M ESPE) after 2 bleaching regimens. Methods: Sixty cylindrical specimens (10 × 2 mm) of each of the 2 composites were prepared and divided into 6 groups (n = 20): groups 1, 2: no treatment; groups 3, 4: 10% carbamide peroxide (CP); and groups 5, 6: 35% hydrogen peroxide (HP) plus LED. After treatments, specimens were thermocycled (500 cycles, 5°C/55°C, dwell time 30 minutes). A mechanical roughness tester was employed to measure the surface roughness parameters and the Vickers test to measure microhardness. One-way ANOVA, Tukey and Bonferroni methods with a significance level of 5% were used for the statistical analysis. Results: For SonicFill™, there was no statistically significant difference in microhardness between the control group (no. 1) and the bleached groups (nos. 3, 5), but there was difference between CP and HP treatments; for Filtek™ Supreme XTE, there was no significant difference in microhardness among all groups. There was no significant difference in average roughness (Ra ) and the root mean square of the roughness (Rq ) among all groups. The mean roughness depth (Rz ) parameter showed no statistically significant differences among all groups for SonicFill™, but in Filtek™ Supreme XTE, there was a significant increase between control and bleaching treatments; roughness skewness (Rsk ) showed no statisticallyBackground: The aim of this study was to evaluate the roughness and microhardness of SonicFill™ (Kerr), and compare it with Filtek™ Supreme XTE (3M ESPE) after 2 bleaching regimens. Methods: Sixty cylindrical specimens (10 × 2 mm) of each of the 2 composites were prepared and divided into 6 groups (n = 20): groups 1, 2: no treatment; groups 3, 4: 10% carbamide peroxide (CP); and groups 5, 6: 35% hydrogen peroxide (HP) plus LED. After treatments, specimens were thermocycled (500 cycles, 5°C/55°C, dwell time 30 minutes). A mechanical roughness tester was employed to measure the surface roughness parameters and the Vickers test to measure microhardness. One-way ANOVA, Tukey and Bonferroni methods with a significance level of 5% were used for the statistical analysis. Results: For SonicFill™, there was no statistically significant difference in microhardness between the control group (no. 1) and the bleached groups (nos. 3, 5), but there was difference between CP and HP treatments; for Filtek™ Supreme XTE, there was no significant difference in microhardness among all groups. There was no significant difference in average roughness (Ra ) and the root mean square of the roughness (Rq ) among all groups. The mean roughness depth (Rz ) parameter showed no statistically significant differences among all groups for SonicFill™, but in Filtek™ Supreme XTE, there was a significant increase between control and bleaching treatments; roughness skewness (Rsk ) showed no statistically significant differences among all groups for SonicFill™ and Filtek™ Supreme XTE, except for nos. 2 and 4, where the Rsk increased with CP. Conclusions: The microhardness of Filtek™ Supreme XTE is less affected by bleaching than that of SonicFill™. Both bleaching treatments affect Rz in Filtek™ Supreme XTE in contrast to SonicFill™, but only the CP treatment affects the Rsk of Filtek™ Supreme XTE, with no significant effect of SonicFill™. … (more)
- Is Part Of:
- Journal of applied biomaterials & functional materials. Volume 13:Issue 4(2015)
- Journal:
- Journal of applied biomaterials & functional materials
- Issue:
- Volume 13:Issue 4(2015)
- Issue Display:
- Volume 13, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 13
- Issue:
- 4
- Issue Sort Value:
- 2015-0013-0004-0000
- Page Start:
- 381
- Page End:
- 388
- Publication Date:
- 2015-10
- Subjects:
- Microhardness -- Resin composite -- Roughness -- Tooth bleaching
Biomedical materials -- Periodicals
Bioengineering -- Periodicals
Biomechanics -- Periodicals
610.28 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.jab-fm.com ↗
http://search.ebscohost.com/direct.asp?db=a9h&jid=%22FDR2%22&scope=site ↗ - DOI:
- 10.5301/jabfm.5000239 ↗
- Languages:
- English
- ISSNs:
- 2280-8000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8368.xml