Postnatal dilatation of umbilical cord vessels and its impact on wall integrity: Prerequisite for the artificial placenta. Issue 7 (July 2018)
- Record Type:
- Journal Article
- Title:
- Postnatal dilatation of umbilical cord vessels and its impact on wall integrity: Prerequisite for the artificial placenta. Issue 7 (July 2018)
- Main Title:
- Postnatal dilatation of umbilical cord vessels and its impact on wall integrity: Prerequisite for the artificial placenta
- Authors:
- Peng, Jenny
Rochow, Niels
Dabaghi, Mohammadhossein
Bozanovic, Radenka
Jansen, Jan
Predescu, Dragos
DeFrance, Bryon
Lee, Sau-Young
Fusch, Gerhard
Ravi Selvaganapathy, Ponnambalam
Fusch, Christoph - Abstract:
- Introduction: A lung assist device, which acts as an artificial placenta, can provide additional gas exchange for preterm and term newborns with respiratory failure. The concept of the lung assist device requires a large bore access via umbilical vessels to allow pumpless extracorporeal blood flow rates up to 30 mL/kg/min. After birth, constricted umbilical vessels need to be reopened for vascular access. The objective is to study the impact of umbilical vessel expansion on vessel integrity for achieving large bore access. Methods: Umbilical cords from healthy term deliveries were cannulated and dilatated with percutaneous transluminal angioplasty catheters in 1 mm increments from 4 to 8 mm for umbilical artery and from 4 to 15 mm for umbilical vein, n = 6 per expansion diameter. Paraffin-embedded transverse sections of dilated and control samples were HE & Van Gieson stained. Effects of dilatation, shown by splitting, were measured. Results: Umbilical vessel expansion led to concentric splitting, shown by areas devoid of extracellular matrix and nuclei in the tunica intima and media. No radial splitting was observed. Results suggest an expansion threshold of umbilical artery at 6 mm and umbilical vein at 7 mm, while maximal splitting was observed above this threshold (3.6 ± 0.8%, p = 0.043 for umbilical artery 7 mm and 6.3 ± 1.8%, p = 0.048 for umbilical vein 8 mm). Endothelial cell sloughing was present in all dilated samples but not in the control samples. Conclusion:Introduction: A lung assist device, which acts as an artificial placenta, can provide additional gas exchange for preterm and term newborns with respiratory failure. The concept of the lung assist device requires a large bore access via umbilical vessels to allow pumpless extracorporeal blood flow rates up to 30 mL/kg/min. After birth, constricted umbilical vessels need to be reopened for vascular access. The objective is to study the impact of umbilical vessel expansion on vessel integrity for achieving large bore access. Methods: Umbilical cords from healthy term deliveries were cannulated and dilatated with percutaneous transluminal angioplasty catheters in 1 mm increments from 4 to 8 mm for umbilical artery and from 4 to 15 mm for umbilical vein, n = 6 per expansion diameter. Paraffin-embedded transverse sections of dilated and control samples were HE & Van Gieson stained. Effects of dilatation, shown by splitting, were measured. Results: Umbilical vessel expansion led to concentric splitting, shown by areas devoid of extracellular matrix and nuclei in the tunica intima and media. No radial splitting was observed. Results suggest an expansion threshold of umbilical artery at 6 mm and umbilical vein at 7 mm, while maximal splitting was observed above this threshold (3.6 ± 0.8%, p = 0.043 for umbilical artery 7 mm and 6.3 ± 1.8%, p = 0.048 for umbilical vein 8 mm). Endothelial cell sloughing was present in all dilated samples but not in the control samples. Conclusion: The suggested thresholds for safe expansions are similar to in utero umbilical vessel diameters and demonstrate a proof of concept for attaining large bore access for the lung assist device. … (more)
- Is Part Of:
- International journal of artificial organs. Volume 41:Issue 7(2018:Jul.)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 41:Issue 7(2018:Jul.)
- Issue Display:
- Volume 41, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 41
- Issue:
- 7
- Issue Sort Value:
- 2018-0041-0007-0000
- Page Start:
- 393
- Page End:
- 399
- Publication Date:
- 2018-07
- Subjects:
- Catheter -- respiratory insufficiency -- respiratory distress -- newborn -- preterm infant -- artery -- vein -- vessel wall integrity -- vascular dilatation
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.1177/0391398818763663 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8371.xml