Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations. (November 2017)
- Record Type:
- Journal Article
- Title:
- Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations. (November 2017)
- Main Title:
- Ambient neutron dose equivalent during proton therapy using wobbling scanning system: Measurements and calculations
- Authors:
- Lin, Yung-Chieh
Lee, Chung-Chi
Chao, Tsi-Chian
Tsai, Hui-Yu - Abstract:
- Abstract: Neutron production is a concern in proton therapy, particularly in scattering proton beam delivery systems. Despite this fact, little is known about the effects of secondary neutron exposure around wobbling scattered proton treatment nozzles. The objective of this study was to estimate the neutron dose level resulting from the use of a wobbling scattered proton treatment unit. We applied the Monte Carlo method for predict the ambient neutron dose equivalent, H *(10), per absorbed dose at the treatment isocenter, D, in the proton therapy center of Chang Gung Memorial Hospital, Linkou, Taiwan. For a 190-MeV proton beam, H * ( 10 ) / D values typically decreased with the distance from the isocenter, being 1.106 mSv/Gy at the isocenter versus 0.112 mSv/Gy at a distance of 150 cm from the isocenter. The H * ( 10 ) / D values generally decreased as the neutron receptors moved away from the isocenter, and increased when the angle from the initial beam axis increased. The ambient neutron dose equivalents were observed to be slightly lower in the direction of multileaf collimator movement. For radiation protection, the central axis of a proton-treated patient is suggested to be at the 0° angle of the beam. If the beam direction at the 90° angle is necessary, the patient axis is suggested to be along with the direction of MLC movement. Our study provides the neutron dose level and neutron energy fluence for the first wobbling proton system at the proton therapy center ofAbstract: Neutron production is a concern in proton therapy, particularly in scattering proton beam delivery systems. Despite this fact, little is known about the effects of secondary neutron exposure around wobbling scattered proton treatment nozzles. The objective of this study was to estimate the neutron dose level resulting from the use of a wobbling scattered proton treatment unit. We applied the Monte Carlo method for predict the ambient neutron dose equivalent, H *(10), per absorbed dose at the treatment isocenter, D, in the proton therapy center of Chang Gung Memorial Hospital, Linkou, Taiwan. For a 190-MeV proton beam, H * ( 10 ) / D values typically decreased with the distance from the isocenter, being 1.106 mSv/Gy at the isocenter versus 0.112 mSv/Gy at a distance of 150 cm from the isocenter. The H * ( 10 ) / D values generally decreased as the neutron receptors moved away from the isocenter, and increased when the angle from the initial beam axis increased. The ambient neutron dose equivalents were observed to be slightly lower in the direction of multileaf collimator movement. For radiation protection, the central axis of a proton-treated patient is suggested to be at the 0° angle of the beam. If the beam direction at the 90° angle is necessary, the patient axis is suggested to be along with the direction of MLC movement. Our study provides the neutron dose level and neutron energy fluence for the first wobbling proton system at the proton therapy center of Chang Gung Memorial Hospital. Highlights: Wobbling scatter nozzle has lower neutron than that of passive scatter nozzle. Wobbling scatter nozzle has more neutron than that of a pencil-scanning system. Neutron dose equivalent per absorbed dose generally increased with increasing angle. We observe different H * ( 10 ) / D in the MLC movement and MLC width directions. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 140(2017)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 140(2017)
- Issue Display:
- Volume 140, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 140
- Issue:
- 2017
- Issue Sort Value:
- 2017-0140-2017-0000
- Page Start:
- 290
- Page End:
- 294
- Publication Date:
- 2017-11
- Subjects:
- Proton therapy -- Secondary neutron -- Wobbling scatter nozzle -- WENDI-II -- Monte Carlo -- H*(10)/D
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2017.01.025 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8345.xml