Choosing a new CD4 technology: Can statistical method comparison tools influence the decision?. Issue 6 (24th May 2017)
- Record Type:
- Journal Article
- Title:
- Choosing a new CD4 technology: Can statistical method comparison tools influence the decision?. Issue 6 (24th May 2017)
- Main Title:
- Choosing a new CD4 technology: Can statistical method comparison tools influence the decision?
- Authors:
- Scott, Lesley E.
Kestens, Luc
Pattanapanyasat, Kovit
Sukapirom, Kasma
Stevens, Wendy S. - Abstract:
- Abstract : Background: Method comparison tools are used to determine the accuracy, precision, agreement, and clinical relevance of a new or improved technology versus a reference technology. Guidelines for the most appropriate method comparison tools as well as their acceptable limits are lacking and not standardized for CD4 counting technologies. Methods: Different method comparison tools were applied to a previously published CD4 dataset ( n = 150 data pairs) evaluating five different CD4 counting technologies (TruCOUNT, Dual Platform, FACSCount, Easy CD4, CyFlow) on a single specimen. Bland–Altman, percentage similarity, percent difference, concordance correlation, sensitivity, specificity and misclassification method comparison tools were applied as well as visualization of agreement with Passing Bablock and Bland–Altman scatter plots. Results: The FACSCount (median CD4 = 245 cells/µl) was considered the reference for method comparison. An algorithm was developed using best practices of the most applicable method comparison tools, and together with a modified heat map was found useful for method comparison of CD4 qualitative and quantitative results. The algorithm applied the concordance correlation for overall accuracy and precision, then standard deviation of the absolute bias and percentage similarity coefficient of variation to identify agreement, and lastly sensitivity and misclassification rates for clinical relevance. Conclusion: Combining method comparison toolsAbstract : Background: Method comparison tools are used to determine the accuracy, precision, agreement, and clinical relevance of a new or improved technology versus a reference technology. Guidelines for the most appropriate method comparison tools as well as their acceptable limits are lacking and not standardized for CD4 counting technologies. Methods: Different method comparison tools were applied to a previously published CD4 dataset ( n = 150 data pairs) evaluating five different CD4 counting technologies (TruCOUNT, Dual Platform, FACSCount, Easy CD4, CyFlow) on a single specimen. Bland–Altman, percentage similarity, percent difference, concordance correlation, sensitivity, specificity and misclassification method comparison tools were applied as well as visualization of agreement with Passing Bablock and Bland–Altman scatter plots. Results: The FACSCount (median CD4 = 245 cells/µl) was considered the reference for method comparison. An algorithm was developed using best practices of the most applicable method comparison tools, and together with a modified heat map was found useful for method comparison of CD4 qualitative and quantitative results. The algorithm applied the concordance correlation for overall accuracy and precision, then standard deviation of the absolute bias and percentage similarity coefficient of variation to identify agreement, and lastly sensitivity and misclassification rates for clinical relevance. Conclusion: Combining method comparison tools is more useful in evaluating CD4 technologies compared to a reference CD4. This algorithm should be further validated using CD4 external quality assessment data and studies with larger sample sizes. © 2017 International Clinical Cytometry Society … (more)
- Is Part Of:
- Cytometry. Volume 92:Issue 6(2017)
- Journal:
- Cytometry
- Issue:
- Volume 92:Issue 6(2017)
- Issue Display:
- Volume 92, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 92
- Issue:
- 6
- Issue Sort Value:
- 2017-0092-0006-0000
- Page Start:
- 465
- Page End:
- 475
- Publication Date:
- 2017-05-24
- Subjects:
- method comparison -- CD4 technology -- statistical algorithm -- Bland–Altman -- percentage similarity -- concordance correlation -- misclassification
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.21522 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: