Automation for clinical CD4 T‐cell enumeration, a desirable tool in the hands of skilled operators. Issue 6 (30th March 2016)
- Record Type:
- Journal Article
- Title:
- Automation for clinical CD4 T‐cell enumeration, a desirable tool in the hands of skilled operators. Issue 6 (30th March 2016)
- Main Title:
- Automation for clinical CD4 T‐cell enumeration, a desirable tool in the hands of skilled operators
- Authors:
- Diallo, T. O.
Bergeron, M.
Seely, P.
Yang, X.
Ding, T.
Plews, M.
Sandstrom, P.
Ball, T. B.
Meyers, A. F. A. - Abstract:
- Abstract : Background: Automation in HIV clinical flow cytometry when appropriately applied brings considerable standardisation benefits. The Canadian Immunology Quality Assessment Program (CIQAP) detected situations where operators did not manually override automated software in the event of improper output on the Epics XL and FC500 CD4 immunophenotyping platforms. The automated gating algorithm identifies lymphocytes using a double gate strategy based on CD45 × side scatter (SS) gating and a light scatter FS × SS gate known to fail with sub optimal specimens. Method: To generate correct interpretation and results CIQAP introduced a simple protocol modification, bypassing the light scatter gate to include all cells characterized by the CD45 gate. Seventeen problem cases were reanalysed for both absolute and relative T‐cell subsets accuracy and compared to the CIQAP group mean values. Results were found to be associated with the percentage of lymphocytes excluded by the automated light scatter gate. Results: The modified manual protocol resolved poor performance in 14 instances out of 17 problem cases. It was found to improve accuracy when the light scatter gate excluded greater than 5% of the cells. The remaining three cases had a lymphocyte recovery of greater than 94.6% in the original automated analysis. Conclusion: There is a risk in relying solely on automated gating procedures when using the Epics XL and FC500 CD4 immunophenotyping platforms. Laboratory managers haveAbstract : Background: Automation in HIV clinical flow cytometry when appropriately applied brings considerable standardisation benefits. The Canadian Immunology Quality Assessment Program (CIQAP) detected situations where operators did not manually override automated software in the event of improper output on the Epics XL and FC500 CD4 immunophenotyping platforms. The automated gating algorithm identifies lymphocytes using a double gate strategy based on CD45 × side scatter (SS) gating and a light scatter FS × SS gate known to fail with sub optimal specimens. Method: To generate correct interpretation and results CIQAP introduced a simple protocol modification, bypassing the light scatter gate to include all cells characterized by the CD45 gate. Seventeen problem cases were reanalysed for both absolute and relative T‐cell subsets accuracy and compared to the CIQAP group mean values. Results were found to be associated with the percentage of lymphocytes excluded by the automated light scatter gate. Results: The modified manual protocol resolved poor performance in 14 instances out of 17 problem cases. It was found to improve accuracy when the light scatter gate excluded greater than 5% of the cells. The remaining three cases had a lymphocyte recovery of greater than 94.6% in the original automated analysis. Conclusion: There is a risk in relying solely on automated gating procedures when using the Epics XL and FC500 CD4 immunophenotyping platforms. Laboratory managers have the responsibility to intervene when required. EQA providers are equally responsible to alert the clinical laboratories of the need to update operator training to deal with stressed specimens. © 2016 International Clinical Cytometry Society … (more)
- Is Part Of:
- Cytometry. Volume 92:Issue 6(2017)
- Journal:
- Cytometry
- Issue:
- Volume 92:Issue 6(2017)
- Issue Display:
- Volume 92, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 92
- Issue:
- 6
- Issue Sort Value:
- 2017-0092-0006-0000
- Page Start:
- 445
- Page End:
- 450
- Publication Date:
- 2016-03-30
- Subjects:
- flow cytometer -- Epics XL and FC500 software -- automation -- quality control -- CD4 testing -- immunophenotyping -- HIV
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.21370 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8347.xml