One-year efficacy and safety of the Trufill DCS Orbit and Orbit Galaxy detachable coils in the endovascular treatment of intracranial aneurysms: Results from the TRULINE study. Issue 5 (October 2017)
- Record Type:
- Journal Article
- Title:
- One-year efficacy and safety of the Trufill DCS Orbit and Orbit Galaxy detachable coils in the endovascular treatment of intracranial aneurysms: Results from the TRULINE study. Issue 5 (October 2017)
- Main Title:
- One-year efficacy and safety of the Trufill DCS Orbit and Orbit Galaxy detachable coils in the endovascular treatment of intracranial aneurysms: Results from the TRULINE study
- Authors:
- Gory, Benjamin
Huot, Laure
Riva, Roberto
Labeyrie, Paul E
Levrier, Olivier
Lebedinsky, Ariel
Brunel, Hervé
Gauvrit, Jean-Yves
Blanc, Raphael
Chabert, Emmanuel
Derex, Laurent
Emery, Evelyne
Nicolas, Arnaud
Desal, Hubert
Rodesch, Georges
Turjman, Francis - Abstract:
- Background and purpose: No series reported the mid-term results of Trufill DCS Orbit and Orbit Galaxy detachable coils with independent evaluation. We present the one-year safety and efficacy of these coils in real-life routine clinical practice. Methods: A total of 167 patients with 167 aneurysms (39.1% ruptured) were enrolled in the prospective TRULINE study. The primary endpoint was the safety, assessed by the combined morbidity-mortality rate observed since the time of the procedure and up to one-year follow-up. For safety, primary analyses were performed on intent-to-treat population (attempted coils procedure) and all adverse events have been reviewed by an independent Data Safety Monitoring Board. For efficacy, primary analyses were performed on the per-protocol population (patients treated with more than 70% of Trufill coils and not retreated during the follow-up period) and an independent core laboratory evaluated angiographic results. Results: At one-year post-procedure, neurologic impairment was observed in 6.5% (95% confidence interval: 3.5–11.8) of the patients, and 2.6% (95% confidence interval: 1.0–6.8) had a permanent neurological deterioration. Three deaths were observed, unrelated to the procedure or coils. At one year, complete occlusion was seen in 52 aneurysms (54.2%), neck remnant in 28 aneurysms (29.2%), and aneurysm remnant in 16 aneurysms (16.7%). During the one-year follow-up, the overall incidence of recurrence was 30.2% with a mean interval ofBackground and purpose: No series reported the mid-term results of Trufill DCS Orbit and Orbit Galaxy detachable coils with independent evaluation. We present the one-year safety and efficacy of these coils in real-life routine clinical practice. Methods: A total of 167 patients with 167 aneurysms (39.1% ruptured) were enrolled in the prospective TRULINE study. The primary endpoint was the safety, assessed by the combined morbidity-mortality rate observed since the time of the procedure and up to one-year follow-up. For safety, primary analyses were performed on intent-to-treat population (attempted coils procedure) and all adverse events have been reviewed by an independent Data Safety Monitoring Board. For efficacy, primary analyses were performed on the per-protocol population (patients treated with more than 70% of Trufill coils and not retreated during the follow-up period) and an independent core laboratory evaluated angiographic results. Results: At one-year post-procedure, neurologic impairment was observed in 6.5% (95% confidence interval: 3.5–11.8) of the patients, and 2.6% (95% confidence interval: 1.0–6.8) had a permanent neurological deterioration. Three deaths were observed, unrelated to the procedure or coils. At one year, complete occlusion was seen in 52 aneurysms (54.2%), neck remnant in 28 aneurysms (29.2%), and aneurysm remnant in 16 aneurysms (16.7%). During the one-year follow-up, the overall incidence of recurrence was 30.2% with a mean interval of 13.8 ± 4.5 months and the retreatment for major recanalization was needed in nine patients (6.3%). Conclusions: The TRULINE study confirms that endovascular coiling with Trufill DCS Orbit and Orbit Galaxy detachable coils is safe and effective. … (more)
- Is Part Of:
- Interventional neuroradiology. Volume 23:Issue 5(2017:Oct.)
- Journal:
- Interventional neuroradiology
- Issue:
- Volume 23:Issue 5(2017:Oct.)
- Issue Display:
- Volume 23, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 23
- Issue:
- 5
- Issue Sort Value:
- 2017-0023-0005-0000
- Page Start:
- 485
- Page End:
- 491
- Publication Date:
- 2017-10
- Subjects:
- Intracranial aneurysms -- coiling -- endovascular treatment -- recanalization
Nervous system -- Interventional radiology -- Periodicals
Nervous system -- Radiography -- Periodicals
Nervous System Diseases -- Periodicals -- radiography
Neuroradiography -- Periodicals
Radiography, Interventional -- Periodicals
Nervous system -- Radiography
Periodicals
617.4805 - Journal URLs:
- http://ine.sagepub.com/ ↗
http://web.ebscohost.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1673/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1591019917717576 ↗
- Languages:
- English
- ISSNs:
- 1591-0199
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8343.xml