Discrepancies in measuring bladder volumes with bedside ultrasound and bladder scanning in the intensive care unit: A pilot study. (May 2018)
- Record Type:
- Journal Article
- Title:
- Discrepancies in measuring bladder volumes with bedside ultrasound and bladder scanning in the intensive care unit: A pilot study. (May 2018)
- Main Title:
- Discrepancies in measuring bladder volumes with bedside ultrasound and bladder scanning in the intensive care unit: A pilot study
- Authors:
- Prentice, Donna M
Sona, Carrie
Wessman, Brian T
Ablordeppey, Enyo A
Isakow, Warren
Arroyo, Cassandra
Schallom, Marilyn - Abstract:
- Objective: Intensive care unit patients are at risk for catheter-associated urinary tract infection. Earlier removal of catheters may be possible with accurate measurement of bladder volume. The purpose was to compare measured bladder volumes with bedside ultrasound, bladder scanner, and urine volume. Design: Prospective correlational descriptive study. Setting: Surgical/trauma intensive care unit and medical intensive care unit. Patients: Renal dialysis patients with less than 100 ml of urine in 24 h prior to urinary catheter removal and patients with suspected catheter obstruction. Measurements and main results: A physician trained in ultrasound and an advanced practice registered nurse trained in bladder scanning measured bladder volume; each blinded to the other's measurement. Device used first (ultrasound or bladder scanner) alternated daily. The intensive care unit team determined need for intermittent catheterization or treatment for suspected obstruction. Fifty-one measurements from 13 patients were obtained with results reported in milliliters. Ultrasound measurements were a mean volume of 72.1 ± 127 (range: 1.7–666) and the bladder scanner measurements were 117 ± 131 (0–529). On six occasions in five dialysis patients, urine volume measurement was available. The mean difference in ultrasound–urine volume mean difference was 0.5 ± 37.8 (range: −68 to 38.2) and the bladder scanner–urine volume was 132 ± 167 (−72 to 397). Two patients with suspected catheterObjective: Intensive care unit patients are at risk for catheter-associated urinary tract infection. Earlier removal of catheters may be possible with accurate measurement of bladder volume. The purpose was to compare measured bladder volumes with bedside ultrasound, bladder scanner, and urine volume. Design: Prospective correlational descriptive study. Setting: Surgical/trauma intensive care unit and medical intensive care unit. Patients: Renal dialysis patients with less than 100 ml of urine in 24 h prior to urinary catheter removal and patients with suspected catheter obstruction. Measurements and main results: A physician trained in ultrasound and an advanced practice registered nurse trained in bladder scanning measured bladder volume; each blinded to the other's measurement. Device used first (ultrasound or bladder scanner) alternated daily. The intensive care unit team determined need for intermittent catheterization or treatment for suspected obstruction. Fifty-one measurements from 13 patients were obtained with results reported in milliliters. Ultrasound measurements were a mean volume of 72.1 ± 127 (range: 1.7–666) and the bladder scanner measurements were 117 ± 131 (0–529). On six occasions in five dialysis patients, urine volume measurement was available. The mean difference in ultrasound–urine volume mean difference was 0.5 ± 37.8 (range: −68 to 38.2) and the bladder scanner–urine volume was 132 ± 167 (−72 to 397). Two patients with suspected catheter obstructions had ultrasound, bladder scanner, urine volume measurements, respectively: (1) 539, 51, >300 (began voiding before catheter replaced); (2) 666, 68, 1000 with catheter replacement. Conditions leading to greatest differences were obesity, indwelling catheter and ascites. Conclusions: These results demonstrate the inaccuracy of the bladder scanner. Ultrasound measurements appear more accurate. To remove urinary catheters in patients with minimal to low urine output, serial ultrasound measurements can be used to monitor bladder volumes and return of renal function. … (more)
- Is Part Of:
- Journal of the Intensive Care Society. Volume 19:Number 2(2018:May)
- Journal:
- Journal of the Intensive Care Society
- Issue:
- Volume 19:Number 2(2018:May)
- Issue Display:
- Volume 19, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 2
- Issue Sort Value:
- 2018-0019-0002-0000
- Page Start:
- 122
- Page End:
- 126
- Publication Date:
- 2018-05
- Subjects:
- Catheter-associated urinary tract infection -- ultrasound -- bladder scanner -- urine volume
Critical care medicine -- Periodicals
Intensive care units -- Periodicals
616.028 - Journal URLs:
- http://www.uk.sagepub.com/journals/Journal202320 ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1751143717740805 ↗
- Languages:
- English
- ISSNs:
- 1751-1437
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8346.xml