Effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation: A randomized comparison between single- and double-lumen tubes. Issue 1 (January 2018)
- Record Type:
- Journal Article
- Title:
- Effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation: A randomized comparison between single- and double-lumen tubes. Issue 1 (January 2018)
- Main Title:
- Effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation: A randomized comparison between single- and double-lumen tubes
- Authors:
- Kim, Tae Kyong
Hong, Deok Man
Lee, Seo Hee
Paik, Hyesun
Min, Se Hee
Seo, Jeong-Hwa
Jung, Chul-Woo
Bahk, Jae-Hyon - Abstract:
- Objective: To investigate the effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation with a single-lumen tube (SLT) or a double-lumen tube (DLT). Methods: Patients scheduled for thoracic surgery requiring one-lung ventilation were randomly allocated to either the SLT or DLT group. All patients received a target-controlled infusion of propofol and a predetermined concentration of remifentanil. Haemodynamic parameters during intubation were recorded. The effect-site concentration of remifentanil was determined using a delayed up-and-down sequential allocation method. Results: A total of 92 patients were enrolled in the study. The effective effect-site concentrations of remifentanil required to blunt haemodynamic responses in 50% of patients (EC50 ) estimated by isotonic regression with bootstrapping was higher in the DLT than the SLT group (8.5 ng/ml [95% confidence interval (CI) 8.0–9.5 ng/ml] versus 6.5 ng/ml [95% CI 5.6–6.7 ng/ml], respectively). Similarly, the effective effect-site concentrations of remifentanil in 95% of patients in the DLT group was higher than the SLT group (9.9 ng/ml [95% CI 9.8–10.0 ng/ml] versus 7.0 ng/ml [95% CI 6.9–7.0 ng/ml], respectively). Conclusions: This study demonstrated that a DLT requires a 30% higher EC50 of remifentanil than does an SLT to blunt haemodynamic responses during tracheal intubation when combined with a target-controlled infusion of propofol. Trial registration:Objective: To investigate the effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation with a single-lumen tube (SLT) or a double-lumen tube (DLT). Methods: Patients scheduled for thoracic surgery requiring one-lung ventilation were randomly allocated to either the SLT or DLT group. All patients received a target-controlled infusion of propofol and a predetermined concentration of remifentanil. Haemodynamic parameters during intubation were recorded. The effect-site concentration of remifentanil was determined using a delayed up-and-down sequential allocation method. Results: A total of 92 patients were enrolled in the study. The effective effect-site concentrations of remifentanil required to blunt haemodynamic responses in 50% of patients (EC50 ) estimated by isotonic regression with bootstrapping was higher in the DLT than the SLT group (8.5 ng/ml [95% confidence interval (CI) 8.0–9.5 ng/ml] versus 6.5 ng/ml [95% CI 5.6–6.7 ng/ml], respectively). Similarly, the effective effect-site concentrations of remifentanil in 95% of patients in the DLT group was higher than the SLT group (9.9 ng/ml [95% CI 9.8–10.0 ng/ml] versus 7.0 ng/ml [95% CI 6.9–7.0 ng/ml], respectively). Conclusions: This study demonstrated that a DLT requires a 30% higher EC50 of remifentanil than does an SLT to blunt haemodynamic responses during tracheal intubation when combined with a target-controlled infusion of propofol. Trial registration: Clinicaltrials.gov identifier: NCT01542099. … (more)
- Is Part Of:
- Journal of international medical research. Volume 46:Issue 1(2018)
- Journal:
- Journal of international medical research
- Issue:
- Volume 46:Issue 1(2018)
- Issue Display:
- Volume 46, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 1
- Issue Sort Value:
- 2018-0046-0001-0000
- Page Start:
- 430
- Page End:
- 439
- Publication Date:
- 2018-01
- Subjects:
- Double-lumen tube placement -- effect-site concentration -- remifentanil
Medicine -- Periodicals
Pharmacology -- Periodicals
610.5 - Journal URLs:
- http://imr.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0300060517721072 ↗
- Languages:
- English
- ISSNs:
- 0300-0605
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8343.xml