A Novel Method to Measure Artificial Eye Motility. Issue 6 (November 2017)
- Record Type:
- Journal Article
- Title:
- A Novel Method to Measure Artificial Eye Motility. Issue 6 (November 2017)
- Main Title:
- A Novel Method to Measure Artificial Eye Motility
- Authors:
- Mourits, Daphne L.
Hartong, Dyonne T.
van Beek, Johannes H. M.
Witte, Birgit I.
Tan, H. Stevie
Moll, Annette C. - Abstract:
- Abstract : Purpose: To measure objectively, reproducibly, and noninvasively artificial eye motility, a fundamental aspect in the (cosmetic) outcome of enucleation. Method: A gaze- and pupil-tracking system, the "iView X, " was implemented to measure horizontal eye motility. The system, with adjusted software, was tested with patients wearing 1 prosthetic eye after enucleation for retinoblastoma. Measurements were repeated 5 times in every patient and analyses were performed twice by 2 independent observers. Reproducibility was tested via linear mixed models. After the implementation of the method, more data were obtained, including more patients with a history of enucleation for the treatment of retinoblastoma for eye tracker measurement, and differences in motility percentages between implant types and sizes were analyzed via Mann-Whitney U tests. Results: The intraclass correlation coefficient of the interobserver variable in the patient test group (n = 27, 6–53 years) was 0.98 and 0.96 for measurement of left gaze and right gaze, respectively. Intraobserver variation was <0.001. In the total of 58 included patients for comparative analysis, mean difference of prosthesis motility compared with the contralateral eye in abduction was 57.1% (range 3.2–91.5%); in adduction 65.8% (range 24.0–92.0%). No statistical differences were found between the different implant types and sizes. Conclusion: Motility measurements of the prosthetic eye in comparison to the contralateral eyeAbstract : Purpose: To measure objectively, reproducibly, and noninvasively artificial eye motility, a fundamental aspect in the (cosmetic) outcome of enucleation. Method: A gaze- and pupil-tracking system, the "iView X, " was implemented to measure horizontal eye motility. The system, with adjusted software, was tested with patients wearing 1 prosthetic eye after enucleation for retinoblastoma. Measurements were repeated 5 times in every patient and analyses were performed twice by 2 independent observers. Reproducibility was tested via linear mixed models. After the implementation of the method, more data were obtained, including more patients with a history of enucleation for the treatment of retinoblastoma for eye tracker measurement, and differences in motility percentages between implant types and sizes were analyzed via Mann-Whitney U tests. Results: The intraclass correlation coefficient of the interobserver variable in the patient test group (n = 27, 6–53 years) was 0.98 and 0.96 for measurement of left gaze and right gaze, respectively. Intraobserver variation was <0.001. In the total of 58 included patients for comparative analysis, mean difference of prosthesis motility compared with the contralateral eye in abduction was 57.1% (range 3.2–91.5%); in adduction 65.8% (range 24.0–92.0%). No statistical differences were found between the different implant types and sizes. Conclusion: Motility measurements of the prosthetic eye in comparison to the contralateral eye using the iView X system are reproducible and reliable. This is, to the authors' knowledge, the first easy applicable, noninvasive, reproducible, and commercially available instrument to evaluate prosthesis motility. With the adjusted software program (freely available on request), a similar objective measurement can be performed worldwide. The implant size or type did not influence the outcome of the motility measurement; this finding deserves additional study. Abstract : Artificial eye motility measurement can be noninvasively and reliably performed with the presented eye tracker technique, facilitating comparative motility studies. … (more)
- Is Part Of:
- Ophthalmic plastic and reconstructive surgery. Volume 33:Issue 6(2017)
- Journal:
- Ophthalmic plastic and reconstructive surgery
- Issue:
- Volume 33:Issue 6(2017)
- Issue Display:
- Volume 33, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 33
- Issue:
- 6
- Issue Sort Value:
- 2017-0033-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-11
- Subjects:
- Eye -- Surgery -- Periodicals
Ophthalmic plastic surgery -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Ophthalmologic Surgical Procedures -- Periodicals
Ophthalmology -- Periodicals
Surgery -- Periodicals
617.70592 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00002341-000000000-00000 ↗
http://www.op-rs.com ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/IOP.0000000000000804 ↗
- Languages:
- English
- ISSNs:
- 0740-9303
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6271.430000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8309.xml