Clinical Effectiveness of Intravenous Exenatide Infusion in Perioperative Glycemic Control after Coronary Artery Bypass Graft Surgery: A Phase II/III Randomized Trial. (November 2017)
- Record Type:
- Journal Article
- Title:
- Clinical Effectiveness of Intravenous Exenatide Infusion in Perioperative Glycemic Control after Coronary Artery Bypass Graft Surgery: A Phase II/III Randomized Trial. (November 2017)
- Main Title:
- Clinical Effectiveness of Intravenous Exenatide Infusion in Perioperative Glycemic Control after Coronary Artery Bypass Graft Surgery
- Authors:
- Besch, Guillaume
Perrotti, Andrea
Mauny, Frederic
Puyraveau, Marc
Baltres, Maude
Flicoteaux, Guillaume
Salomon du Mont, Lucie
Barrucand, Benoit
Samain, Emmanuel
Chocron, Sidney
Pili-Floury, Sebastien - Abstract:
- Abstract : Background: We aimed to assess the clinical effectiveness of intravenous exenatide compared to insulin in perioperative blood glucose control in coronary artery bypass grafting surgery patients. Methods: Patients more than 18 yr old admitted for elective coronary artery bypass grafting were included in a phase II/III nonblinded randomized superiority trial. Current insulin use and creatinine clearance of less than 60 ml/min were exclusion criteria. Two groups were compared: the exenatide group, receiving exenatide (1-h bolus of 0.05 µg/min followed by a constant infusion of 0.025 µg/min), and the control group, receiving insulin therapy. The blood glucose target range was 100 to 139 mg/dl. The primary outcome was the proportion of patients who spent at least 50% of the study period within the target range. The consumption of insulin (Cinsulin ) and the time to start insulin (Tinsulin ) were compared between the two groups. Results: In total, 53 and 51 patients were included and analyzed in the exenatide and control groups, respectively (age: 70 ± 9 vs . 68 ± 11 yr; diabetes mellitus: 12 [23%] vs . 10 [20%]). The primary outcome was observed in 38 (72%) patients in the exenatide group and in 41 (80%) patients in the control group (odds ratio [95% CI] = 0.85 [0.34 to 2.11]; P = 0.30). Cinsulin was significantly lower (60 [40 to 80] vs . 92 [63 to 121] U, P < 0.001), and Tinsulin was significantly longer (12 [7 to 16] vs . 7 [5 to 10] h, P = 0.02) in the exenatideAbstract : Background: We aimed to assess the clinical effectiveness of intravenous exenatide compared to insulin in perioperative blood glucose control in coronary artery bypass grafting surgery patients. Methods: Patients more than 18 yr old admitted for elective coronary artery bypass grafting were included in a phase II/III nonblinded randomized superiority trial. Current insulin use and creatinine clearance of less than 60 ml/min were exclusion criteria. Two groups were compared: the exenatide group, receiving exenatide (1-h bolus of 0.05 µg/min followed by a constant infusion of 0.025 µg/min), and the control group, receiving insulin therapy. The blood glucose target range was 100 to 139 mg/dl. The primary outcome was the proportion of patients who spent at least 50% of the study period within the target range. The consumption of insulin (Cinsulin ) and the time to start insulin (Tinsulin ) were compared between the two groups. Results: In total, 53 and 51 patients were included and analyzed in the exenatide and control groups, respectively (age: 70 ± 9 vs . 68 ± 11 yr; diabetes mellitus: 12 [23%] vs . 10 [20%]). The primary outcome was observed in 38 (72%) patients in the exenatide group and in 41 (80%) patients in the control group (odds ratio [95% CI] = 0.85 [0.34 to 2.11]; P = 0.30). Cinsulin was significantly lower (60 [40 to 80] vs . 92 [63 to 121] U, P < 0.001), and Tinsulin was significantly longer (12 [7 to 16] vs . 7 [5 to 10] h, P = 0.02) in the exenatide group. Conclusions: Exenatide alone at the dose used was not enough to achieve adequate blood glucose control in coronary artery bypass grafting patients, but it reduces overall consumption of insulin and increases the time to initiation of insulin. Abstract : Exenatide alone at the dose used was not enough to achieve adequate blood glucose control in coronary artery bypass grafting patients, but it reduced overall consumption of insulin and increased the time to initiation of insulin. … (more)
- Is Part Of:
- Anesthesiology. Volume 127:Number 5(2017)
- Journal:
- Anesthesiology
- Issue:
- Volume 127:Number 5(2017)
- Issue Display:
- Volume 127, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 127
- Issue:
- 5
- Issue Sort Value:
- 2017-0127-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-11
- Subjects:
- Anesthesiology -- Periodicals
Anesthetics -- Periodicals
Anesthesia -- Periodicals
617.9605 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00000542-000000000-00000 ↗
http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=0003-3022 ↗
http://www.anesthesiology.org ↗
http://journals.lww.com ↗
http://journals.lww.com/anesthesiology/pages/default.aspx ↗ - DOI:
- 10.1097/ALN.0000000000001838 ↗
- Languages:
- English
- ISSNs:
- 0003-3022
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0900.600000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8310.xml