Long-term clinical outcome after implantation of the self-expandable STENTYS stent in a large, multicenter cohort. Issue 7 (November 2017)
- Record Type:
- Journal Article
- Title:
- Long-term clinical outcome after implantation of the self-expandable STENTYS stent in a large, multicenter cohort. Issue 7 (November 2017)
- Main Title:
- Long-term clinical outcome after implantation of the self-expandable STENTYS stent in a large, multicenter cohort
- Authors:
- Gaede, Luise
Liebetrau, Christoph
Dörr, Oliver
Blumenstein, Johannes
Elsässer, Albrecht
Hamm, Christian W.
Möllmann, Helge
Schlundt, Christian
Nef, Holger M.
Achenbach, Stephan - Abstract:
- Abstract : Objective: The objective of the study was to retrospectively evaluate the long-term clinical outcome after implantation of the self-expandable (SE) STENTYS stent in a large multicenter cohort. Background: Incomplete stent apposition is known to cause higher rates of myocardial infarction (MI) and stent thrombosis. Because of its self-expanding features, the SE STENTYS stent adapts to the vessel wall and is therefore expected to minimize malapposition and therefore the rates of MI and stent thrombosis. Patients and methods: Treatment with a total of 351 SE coronary stents was attempted in 314 patients of a cohort from three German institutions between 2011 and 2015. Technical success was achieved with 331/351 (94%) stents. Patients treated successfully with SE stents ( n =298) were followed up using the primary outcome measure of target lesion failure (TLF), a combined endpoint of cardiac mortality, recurrent target vessel MI, acute stent thrombosis, and clinically driven target lesion revascularization. Follow-up was complete in 268/298 (90%) patients with a median follow-up period of 2.5 (interquartile range: 1.4–3.3) years. Results: TLF occurred in 54/298 (18%) patients. Event rates were 7.5% for cardiac mortality, 11.6% for target vessel MI, and 5.2% for clinically driven target lesion revascularization. Acute stent thrombosis occurred in 2/298 (0.7%). Overall, stent thrombosis had an incidence of 2.6% within the follow-up period. ST-elevation MI at baseline (Abstract : Objective: The objective of the study was to retrospectively evaluate the long-term clinical outcome after implantation of the self-expandable (SE) STENTYS stent in a large multicenter cohort. Background: Incomplete stent apposition is known to cause higher rates of myocardial infarction (MI) and stent thrombosis. Because of its self-expanding features, the SE STENTYS stent adapts to the vessel wall and is therefore expected to minimize malapposition and therefore the rates of MI and stent thrombosis. Patients and methods: Treatment with a total of 351 SE coronary stents was attempted in 314 patients of a cohort from three German institutions between 2011 and 2015. Technical success was achieved with 331/351 (94%) stents. Patients treated successfully with SE stents ( n =298) were followed up using the primary outcome measure of target lesion failure (TLF), a combined endpoint of cardiac mortality, recurrent target vessel MI, acute stent thrombosis, and clinically driven target lesion revascularization. Follow-up was complete in 268/298 (90%) patients with a median follow-up period of 2.5 (interquartile range: 1.4–3.3) years. Results: TLF occurred in 54/298 (18%) patients. Event rates were 7.5% for cardiac mortality, 11.6% for target vessel MI, and 5.2% for clinically driven target lesion revascularization. Acute stent thrombosis occurred in 2/298 (0.7%). Overall, stent thrombosis had an incidence of 2.6% within the follow-up period. ST-elevation MI at baseline ( P =0.02) and a dual antiplatelet therapy with clopidogrel for only 6 months ( P =0.04) were the only clinical factors linked to the absence of TLF. Conclusion: Technical success of SE coronary stent implantation in an all-comer cohort of patients was high, although the rate of TLF and stent thrombosis during long-term follow-up was also relatively high. … (more)
- Is Part Of:
- Coronary artery disease. Volume 28:Issue 7(2017:Nov.)
- Journal:
- Coronary artery disease
- Issue:
- Volume 28:Issue 7(2017:Nov.)
- Issue Display:
- Volume 28, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 28
- Issue:
- 7
- Issue Sort Value:
- 2017-0028-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-11
- Subjects:
- incomplete stent apposition -- outcome -- self-aposing stent -- self-expanding stent -- stent thrombosis -- target lesion failure
Coronary heart disease -- Periodicals
Coronary Disease -- Indexes
Coronary Disease -- Periodicals
616.123005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00019501-000000000-00000 ↗
http://www.coronary-artery.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MCA.0000000000000533 ↗
- Languages:
- English
- ISSNs:
- 0954-6928
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3472.049000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8314.xml