Quantitative evaluation of image segmentation incorporating medical consideration functions. Issue 6 (26th May 2015)
- Record Type:
- Journal Article
- Title:
- Quantitative evaluation of image segmentation incorporating medical consideration functions. Issue 6 (26th May 2015)
- Main Title:
- Quantitative evaluation of image segmentation incorporating medical consideration functions
- Authors:
- Kim, Haksoo
Monroe, James I.
Lo, Simon
Yao, Min
Harari, Paul M.
Machtay, Mitchell
Sohn, Jason W. - Abstract:
- Abstract : Purpose: A quantitative and objective metric, the medical similarity index (MSI), has been developed for evaluating the accuracy of a medical image segmentation relative to a reference segmentation. The MSI uses the medical consideration function (MCF) as its basis. Methods: Currently, no indices provide quantitative evaluations of segmentation accuracy with medical considerations. Variations in segmentation can occur due to individual skill levels and medical relevance—curable or palliative intent, boundary uncertainty due to volume averaging, contrast levels, spatial resolution, and unresolved motion all affect the accuracy of a patient segmentation. Current accuracy measuring indices are not medically relevant. For example, undercontouring the tumor volume is not differentiated from overcontouring tumor. Dice similarity coefficient (DSC) and Hausdorff distance (HD) are two similarity measures often used. However, these metrics consider only geometric difference without considering medical implications. Two segments (under‐ vs overcontouring tumor) with similar DSC and HD measures could produce significantly different medical treatment results. The authors are proposing a MSI involving a user‐defined MCF derived from an asymmetric Gaussian function. The shape of the MCF can be determined by a user, reflecting the anatomical location and characteristics of a particular tissue, organ, or tumor type. The peak of MCF is set along the reference contour; the inner andAbstract : Purpose: A quantitative and objective metric, the medical similarity index (MSI), has been developed for evaluating the accuracy of a medical image segmentation relative to a reference segmentation. The MSI uses the medical consideration function (MCF) as its basis. Methods: Currently, no indices provide quantitative evaluations of segmentation accuracy with medical considerations. Variations in segmentation can occur due to individual skill levels and medical relevance—curable or palliative intent, boundary uncertainty due to volume averaging, contrast levels, spatial resolution, and unresolved motion all affect the accuracy of a patient segmentation. Current accuracy measuring indices are not medically relevant. For example, undercontouring the tumor volume is not differentiated from overcontouring tumor. Dice similarity coefficient (DSC) and Hausdorff distance (HD) are two similarity measures often used. However, these metrics consider only geometric difference without considering medical implications. Two segments (under‐ vs overcontouring tumor) with similar DSC and HD measures could produce significantly different medical treatment results. The authors are proposing a MSI involving a user‐defined MCF derived from an asymmetric Gaussian function. The shape of the MCF can be determined by a user, reflecting the anatomical location and characteristics of a particular tissue, organ, or tumor type. The peak of MCF is set along the reference contour; the inner and outer slopes are selected by the user. The discrepancy between the test and reference contours is calculated at each pixel by using a bidirectional local distance measure. The MCF value corresponding to that distance is summed and averaged to produce the MSI. Synthetic segmentations and clinical data from a 15 multi‐institutional trial for a head‐and‐neck case are scored and compared by using MSI, DSC, and Hausdorff distance. Results: The MSI was shown to reflect medical considerations through the choice of MCF penalties for under‐ and overcontouring. Existing similarity scores were either insensitive to medical realities or simply inaccurate. Conclusions: The medical similarity index, a segmentation evaluation metric based on medical considerations, has been proposed, developed, and tested to incorporate clinically relevant considerations beyond geometric parameters alone. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 6(2015)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 6(2015)Part 1
- Issue Display:
- Volume 42, Issue 6, Part 1 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 6
- Part:
- 1
- Issue Sort Value:
- 2015-0042-0006-0001
- Page Start:
- 3013
- Page End:
- 3023
- Publication Date:
- 2015-05-26
- Subjects:
- biological organs -- edge detection -- feature selection -- Gaussian processes -- geometry -- image matching -- image resolution -- image segmentation -- medical image processing -- tumours
Segmentation -- Probability theory, stochastic processes, and statistics -- Geometry, differential geometry, and topology
Biological material, e.g. blood, urine; Haemocytometers -- Methods or arrangements for processing data by operating upon the order or content of the data handled -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general
segmentation -- contour -- similarity index -- Dice -- Hausdorff -- Gaussian
Cancer -- Medical image segmentation -- Tissues -- Radiation treatment -- Electric measurements -- Image guided radiation therapy -- Dosimetry -- Radiosurgery
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4921067 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8328.xml