Cementing a Polyethylene Cup into a Well Fixed Acetabular Metal-on-Metal Resurfacing Component? An Experimental Investigation. Issue 4 (July 2017)
- Record Type:
- Journal Article
- Title:
- Cementing a Polyethylene Cup into a Well Fixed Acetabular Metal-on-Metal Resurfacing Component? An Experimental Investigation. Issue 4 (July 2017)
- Main Title:
- Cementing a Polyethylene Cup into a Well Fixed Acetabular Metal-on-Metal Resurfacing Component? An Experimental Investigation
- Authors:
- Klotz, Matthias C.M.
Jäger, Sebastian
Kretzer, Jan-Philippe
Beckmann, Nicholas A.
Thomsen, Marc
Bitsch, Rudi G. - Abstract:
- Introduction: Adverse reactions to metal debris often indicate revision surgery in metal-on-metal (MoM) hip arthroplasty and an exchange of the MoM bearing into either a metal on polyethylene or a ceramic-on-polyethylene articulation. At the moment the removal of the entire implant system is the most reasonable method. In order to avoid bone loss caused by the removal of a well-fixed acetabular component, the purpose of this study was to measure the stability of a cemented polyethylene (PE) cup in an acetabular hip resurfacing component and to examine if such a method could be suitable for clinical use. Methods: PE cups were cemented into 2 different hip resurfacing components and biomechanical tests were applied to measure failure torques under lever out and rotational load. Results: In all cases failure of the interface between the resurfacing components and the cement layer occurred at a very low load (0.14 Nm-61.50 Nm). Discussion: The early failure occurred due to lacking interdigitation of cement and the polished metal surface. Thus we warn against cementing a PE cup into acetabular hip resurfacing components for clinical use.
- Is Part Of:
- Hip international. Volume 27:Issue 4(2017)
- Journal:
- Hip international
- Issue:
- Volume 27:Issue 4(2017)
- Issue Display:
- Volume 27, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 27
- Issue:
- 4
- Issue Sort Value:
- 2017-0027-0004-0000
- Page Start:
- 373
- Page End:
- 377
- Publication Date:
- 2017-07
- Subjects:
- Biomechanical -- Cement augmentation -- Hip resurfacing -- Salvage procedure
Hip joint -- Pathophysiology -- Periodicals
Hip joint -- Diseases -- Periodicals
Hip joint -- Surgery -- Periodicals
617.581005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/home/hpi ↗ - DOI:
- 10.5301/hipint.5000474 ↗
- Languages:
- English
- ISSNs:
- 1120-7000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8317.xml