A Novel Fluoroscopic Approach to Assessing Patient Positioning in Total Hip Arthroplasty: Accuracy and the Influence of Body Mass Index. Issue 6 (10th November 2016)
- Record Type:
- Journal Article
- Title:
- A Novel Fluoroscopic Approach to Assessing Patient Positioning in Total Hip Arthroplasty: Accuracy and the Influence of Body Mass Index. Issue 6 (10th November 2016)
- Main Title:
- A Novel Fluoroscopic Approach to Assessing Patient Positioning in Total Hip Arthroplasty: Accuracy and the Influence of Body Mass Index
- Authors:
- Lambers, Anton P.
Jennings, Robert
Bucknill, Andrew T. - Abstract:
- Introduction: Accurate prosthetic cup placement is important in total hip arthroplasty (THA) and can be influenced by patient positioning. This study aims to assess the accuracy of patient positioning prior to THA, describe a new technique of assessment, and evaluate the influence of body mass index (BMI) on positioning error. Methods: A consecutive series of 37 patients undergoing unilateral THA were investigated. After patient positioning in lateral decubitus, a lateral fluoroscopic image through the table was taken. The C-arm of the image intensifier was manipulated in 2 planes (coronal, transverse) until a perfect lateral view of the pelvis was obtained, defined as when the native acetabulae were superimposed. Degrees of positioning error in the 2 planes were recorded, along with patient BMI. Results: There were 6 patients (16%) positioned within 2° of true lateral in both planes. A further 21 patients (57%) had an error of 5° or more in at least 1 plane. Mean absolute positioning error was 3.0° (SD 2.2°; range 0°-9°) and 3.0° (SD 3.2°; range 0°-13°) in the transverse and coronal planes respectively. Pelvic adduction in the coronal plane was 4.5 fold more likely than abduction (49% vs. 11%). Correlation was shown between patient BMI and the combined error in the 2 planes (R = 0.48, p = 0.001). Discussion: Fluoroscopic positioning assessment prior to THA demonstrates that significant malpositioning is common and more likely with increasing BMI. This technique may beIntroduction: Accurate prosthetic cup placement is important in total hip arthroplasty (THA) and can be influenced by patient positioning. This study aims to assess the accuracy of patient positioning prior to THA, describe a new technique of assessment, and evaluate the influence of body mass index (BMI) on positioning error. Methods: A consecutive series of 37 patients undergoing unilateral THA were investigated. After patient positioning in lateral decubitus, a lateral fluoroscopic image through the table was taken. The C-arm of the image intensifier was manipulated in 2 planes (coronal, transverse) until a perfect lateral view of the pelvis was obtained, defined as when the native acetabulae were superimposed. Degrees of positioning error in the 2 planes were recorded, along with patient BMI. Results: There were 6 patients (16%) positioned within 2° of true lateral in both planes. A further 21 patients (57%) had an error of 5° or more in at least 1 plane. Mean absolute positioning error was 3.0° (SD 2.2°; range 0°-9°) and 3.0° (SD 3.2°; range 0°-13°) in the transverse and coronal planes respectively. Pelvic adduction in the coronal plane was 4.5 fold more likely than abduction (49% vs. 11%). Correlation was shown between patient BMI and the combined error in the 2 planes (R = 0.48, p = 0.001). Discussion: Fluoroscopic positioning assessment prior to THA demonstrates that significant malpositioning is common and more likely with increasing BMI. This technique may be particularly useful for patients with a BMI of >30 kg m-2. … (more)
- Is Part Of:
- Hip international. Volume 26:Issue 6(2016)
- Journal:
- Hip international
- Issue:
- Volume 26:Issue 6(2016)
- Issue Display:
- Volume 26, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 26
- Issue:
- 6
- Issue Sort Value:
- 2016-0026-0006-0000
- Page Start:
- 550
- Page End:
- 553
- Publication Date:
- 2016-11-10
- Subjects:
- Arthroplasty -- Body mass index -- Fluoroscopy -- Hip -- Patient positioning -- Replacement
Hip joint -- Pathophysiology -- Periodicals
Hip joint -- Diseases -- Periodicals
Hip joint -- Surgery -- Periodicals
617.581005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/home/hpi ↗ - DOI:
- 10.5301/hipint.5000397 ↗
- Languages:
- English
- ISSNs:
- 1120-7000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8308.xml