Upper Extremity Muscle Activity During In-Phase and Anti-Phase Continuous Pushing Tasks. (November 2017)
- Record Type:
- Journal Article
- Title:
- Upper Extremity Muscle Activity During In-Phase and Anti-Phase Continuous Pushing Tasks. (November 2017)
- Main Title:
- Upper Extremity Muscle Activity During In-Phase and Anti-Phase Continuous Pushing Tasks
- Authors:
- Gruevski, Kristina M.
Hodder, Joanne N.
Keir, Peter J. - Abstract:
- Objective: To determine the effect of anti-phase, in-phase bimanual and unimanual simulated industrial pushing tasks and frequency on upper extremity muscle activity. Background: Research investigating symmetrical (in-phase) and asymmetrical (anti-phase) pushing exertions is limited despite a high prevalence in industry. Methods: Fifteen female participants completed five pushing tasks using a dual handle apparatus at three frequencies: 15 cycles per minute (cpm), 30 cpm, and self-selected. Tasks included two bimanual symmetrical pushes (constrained and unconstrained), two bimanual asymmetrical pushes (reciprocating and continuous), and one right unimanual push. Surface electromyography (EMG) from the right anterior, middle, and posterior deltoid (AD, MD, and PD); right and left trapezius (RT and LT); right pectoralis major (PM); and right and left external obliques (REO and LEO) was collected and normalized to maximum voluntary effort. Results: There was a task by frequency interaction in the AD, MD, PD, and RT ( p < .005), where activity in AD, MD, and PD was highest in the continuous task at 15 cpm, but activity was similar across task in 30 cpm and self-selected. Muscle activity coefficient of variation was lowest during continuous task across all frequencies. Conclusion: Continuous, anti-phase pushes and constrained, in-phase pushes had the highest muscle activity demands and the least amount of variability in muscle activity and therefore may present the greatest riskObjective: To determine the effect of anti-phase, in-phase bimanual and unimanual simulated industrial pushing tasks and frequency on upper extremity muscle activity. Background: Research investigating symmetrical (in-phase) and asymmetrical (anti-phase) pushing exertions is limited despite a high prevalence in industry. Methods: Fifteen female participants completed five pushing tasks using a dual handle apparatus at three frequencies: 15 cycles per minute (cpm), 30 cpm, and self-selected. Tasks included two bimanual symmetrical pushes (constrained and unconstrained), two bimanual asymmetrical pushes (reciprocating and continuous), and one right unimanual push. Surface electromyography (EMG) from the right anterior, middle, and posterior deltoid (AD, MD, and PD); right and left trapezius (RT and LT); right pectoralis major (PM); and right and left external obliques (REO and LEO) was collected and normalized to maximum voluntary effort. Results: There was a task by frequency interaction in the AD, MD, PD, and RT ( p < .005), where activity in AD, MD, and PD was highest in the continuous task at 15 cpm, but activity was similar across task in 30 cpm and self-selected. Muscle activity coefficient of variation was lowest during continuous task across all frequencies. Conclusion: Continuous, anti-phase pushes and constrained, in-phase pushes had the highest muscle activity demands and the least amount of variability in muscle activity and therefore may present the greatest risk of injury. Application: Anti-phase pushing is known to have a greater cognitive demand, and this study demonstrated that it also has a greater physical demand when performed continuously. … (more)
- Is Part Of:
- Human factors. Volume 59:Number 7(2018)
- Journal:
- Human factors
- Issue:
- Volume 59:Number 7(2018)
- Issue Display:
- Volume 59, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 7
- Issue Sort Value:
- 2018-0059-0007-0000
- Page Start:
- 1066
- Page End:
- 1077
- Publication Date:
- 2017-11
- Subjects:
- work-related musculoskeletal disorders -- coordinated action -- repetition -- electromyography
Human engineering -- Periodicals
620.82 - Journal URLs:
- http://hfs.sagepub.com/ ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/0018720817714367 ↗
- Languages:
- English
- ISSNs:
- 0018-7208
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8328.xml