Intensity‐modulated radiation therapy dose verification using fluence and portal imaging device. (8th January 2016)
- Record Type:
- Journal Article
- Title:
- Intensity‐modulated radiation therapy dose verification using fluence and portal imaging device. (8th January 2016)
- Main Title:
- Intensity‐modulated radiation therapy dose verification using fluence and portal imaging device
- Authors:
- Sumida, Iori
Yamaguchi, Hajime
Das, Indra J.
Kizaki, Hisao
Aboshi, Keiko
Tsujii, Mari
Yamada, Yuji
Suzuki, Osamu
Seo, Yuji
Isohashi, Fumiaki
Ogawa, Kazuhiko - Abstract:
- Abstract : Patient‐specific quality assurance for intensity‐modulated radiation therapy (IMRT) dose verification is essential. The aim of this study is to provide a new method based on the relative error distribution by comparing the fluence map from the treatment planning system (TPS) and the incident fluence deconvolved from the electronic portal imaging device (EPID) images. This method is validated for 10 head and neck IMRT cases. The fluence map of each beam was exported from the TPS and EPID images of the treatment beams were acquired. Measured EPID images were deconvolved to the incident fluence with proper corrections. The relative error distribution between the TPS fluence map and the incident fluence from the EPID was created. This was also created for a 2D diode array detector. The absolute point dose was measured with an ionization chamber, and the dose distribution was measured by a radiochromic film. In three cases, MLC leaf positions were intentionally changed to create the dose error as much as 5% against the planned dose and our fluence‐based method was tested using gamma index. Absolute errors between the predicted dose of 2D diode detector and of our method and measurements were 1.26 % ± 0.65 % and 0.78 % ± 0.81 % respectively. The gamma passing rate (3% global / 3 mm) of the TPS was higher than that of the 2D diode detector ( p < 0.02 ), and lower than that of the EPID ( p < 0.04 ). The gamma passing rate (2% global / 2 mm) of the TPS was higher than thatAbstract : Patient‐specific quality assurance for intensity‐modulated radiation therapy (IMRT) dose verification is essential. The aim of this study is to provide a new method based on the relative error distribution by comparing the fluence map from the treatment planning system (TPS) and the incident fluence deconvolved from the electronic portal imaging device (EPID) images. This method is validated for 10 head and neck IMRT cases. The fluence map of each beam was exported from the TPS and EPID images of the treatment beams were acquired. Measured EPID images were deconvolved to the incident fluence with proper corrections. The relative error distribution between the TPS fluence map and the incident fluence from the EPID was created. This was also created for a 2D diode array detector. The absolute point dose was measured with an ionization chamber, and the dose distribution was measured by a radiochromic film. In three cases, MLC leaf positions were intentionally changed to create the dose error as much as 5% against the planned dose and our fluence‐based method was tested using gamma index. Absolute errors between the predicted dose of 2D diode detector and of our method and measurements were 1.26 % ± 0.65 % and 0.78 % ± 0.81 % respectively. The gamma passing rate (3% global / 3 mm) of the TPS was higher than that of the 2D diode detector ( p < 0.02 ), and lower than that of the EPID ( p < 0.04 ). The gamma passing rate (2% global / 2 mm) of the TPS was higher than that of the 2D diode detector, while the gamma passing rate of the TPS was lower than that of EPID ( p < 0.02 ). For three modified plans, the predicted dose errors against the measured dose were 1.10%, 2.14%, and − 0.87 % . The predicted dose distributions from the EPID were well matched to the measurements. Our fluence‐based method provides very accurate dosimetry for IMRT patients. The method is simple and can be adapted to any clinic for complex cases. PACS numbers: 87.55.D‐, 87.55.km, 87.55.Qr, 87.57.uq … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 17:Number 1(2016)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 17:Number 1(2016)
- Issue Display:
- Volume 17, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2016-0017-0001-0000
- Page Start:
- 259
- Page End:
- 271
- Publication Date:
- 2016-01-08
- Subjects:
- IMRT -- EPID -- dose reconstruction -- fluence‐based dose calculation -- QA
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v17i1.5899 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8320.xml