On the accuracy of dose prediction near metal fixation devices for spine SBRT. (8th May 2016)
- Record Type:
- Journal Article
- Title:
- On the accuracy of dose prediction near metal fixation devices for spine SBRT. (8th May 2016)
- Main Title:
- On the accuracy of dose prediction near metal fixation devices for spine SBRT
- Authors:
- Cheng, Zhangkai J.
Bromley, Regina M.
Oborn, Brad
Carolan, Martin
Booth, Jeremy T. - Abstract:
- Abstract : The metallic fixations used in surgical procedures to support the spine mechanically usually consist of high‐density materials. Radiation therapy to palliate spinal cord compression can include prophylactic inclusion of potential tumor around the site of such fixation devices. Determination of the correct density and shape of the spine fixation device has a direct effect on the dose calculation of the radiation field. Even with the application of modern computed tomography (CT), under‐ or overestimation of dose, both immediately next to the device and in the surrounding tissues, can occur due to inaccuracies in the dose prediction algorithm. In this study, two commercially available dose prediction algorithms (Eclipse AAA and ACUROS), EGSnrc Monte Carlo, and GAFchromic film measurements were compared for a clinical spine SBRT case to determine their accuracy. An open six‐field plan and a clinical nine‐field IMRT plan were applied to a phantom containing a metal spine fixation device. Dose difference and gamma analysis were performed in and around the tumor region adjacent to the fixation device. Dose calculation inconsistency was observed in the open field plan. However, in the IMRT plan, the dose perturbation effect was not observed beyond 5 mm. Our results suggest that the dose effect of the metal fixation device to the spinal cord and the tumor volume is not observable, and all dose calculation algorithms evaluated can provide clinically acceptable accuracy inAbstract : The metallic fixations used in surgical procedures to support the spine mechanically usually consist of high‐density materials. Radiation therapy to palliate spinal cord compression can include prophylactic inclusion of potential tumor around the site of such fixation devices. Determination of the correct density and shape of the spine fixation device has a direct effect on the dose calculation of the radiation field. Even with the application of modern computed tomography (CT), under‐ or overestimation of dose, both immediately next to the device and in the surrounding tissues, can occur due to inaccuracies in the dose prediction algorithm. In this study, two commercially available dose prediction algorithms (Eclipse AAA and ACUROS), EGSnrc Monte Carlo, and GAFchromic film measurements were compared for a clinical spine SBRT case to determine their accuracy. An open six‐field plan and a clinical nine‐field IMRT plan were applied to a phantom containing a metal spine fixation device. Dose difference and gamma analysis were performed in and around the tumor region adjacent to the fixation device. Dose calculation inconsistency was observed in the open field plan. However, in the IMRT plan, the dose perturbation effect was not observed beyond 5 mm. Our results suggest that the dose effect of the metal fixation device to the spinal cord and the tumor volume is not observable, and all dose calculation algorithms evaluated can provide clinically acceptable accuracy in the case of spinal SBRT, with the tolerance of 95% for gamma criteria of 3 % / 3 mm . PACS number(s): 87.53.bn, 87.53.Ly, 87.55.kd … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 17:Number 3(2016)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 17:Number 3(2016)
- Issue Display:
- Volume 17, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 3
- Issue Sort Value:
- 2016-0017-0003-0000
- Page Start:
- 475
- Page End:
- 485
- Publication Date:
- 2016-05-08
- Subjects:
- spine SBRT -- dose calculation accuracy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v17i3.5536 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8320.xml