Measurement of lacrimal punctum using spectralis domain anterior optical coherence tomography. Issue 7 (28th December 2016)
- Record Type:
- Journal Article
- Title:
- Measurement of lacrimal punctum using spectralis domain anterior optical coherence tomography. Issue 7 (28th December 2016)
- Main Title:
- Measurement of lacrimal punctum using spectralis domain anterior optical coherence tomography
- Authors:
- Sung, Youngje
Park, Jong Seo
Lew, Helen - Abstract:
- Abstract: Purpose: Anterior segment optical coherence tomography (AS‐OCT) was used to image the lacrimal punctum and establish normal punctal parameters including the tear volume inside the punctum. Methods: This study included totally 67 eyes from 38 normal subjects. Punctal parameters and tear meniscus height (TMH) were measured using spectralis OCT anterior‐segment scans. Outer punctal diameter (OPD), punctal depth, tear well diameter (TWD), tear well depth, punctal reserve (PR) and lower eyelid TMH were assessed. Authors defined a 'tear well' as a pool of standing tears in the punctum. Punctal reserve was defined as the difference between punctal depth and tear well depth. Results: Outer punctal diameter was 614.6 ± 195.6 μ m, the punctal depth was 545.8 ± 270.1 μ m, TWD was 229.9 ± 133.8 μ m, the tear well depth was 434.9 ± 247.8 μ m, the PR was 110.9 ± 72.9 μ m, the PR ratio was 0.20 ± 0.17, and the TMH was 222.9 ± 88.8 μ m. The punctal depth decreased significantly according to the patient's age (correlation coefficient = −0.352, respectively). Conclusion: AS‐OCT is useful for improving anatomical understanding of the lacrimal punctal structure. Quantitative punctum and tear well measurements were correlated with TMH.
- Is Part Of:
- Acta ophthalmologica. Volume 95:Issue 7(2017)
- Journal:
- Acta ophthalmologica
- Issue:
- Volume 95:Issue 7(2017)
- Issue Display:
- Volume 95, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 95
- Issue:
- 7
- Issue Sort Value:
- 2017-0095-0007-0000
- Page Start:
- e619
- Page End:
- e624
- Publication Date:
- 2016-12-28
- Subjects:
- lacrimal punctum -- normal population -- optical coherence tomography -- tear dynamics
Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1755-3768 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aos.13322 ↗
- Languages:
- English
- ISSNs:
- 1755-375X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.750500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8316.xml