Excellent long-term results of the Müller acetabular reinforcement ring in primary cup revision: A single-center study of 259 cases after a mean of 10 years' follow-up. (2nd November 2017)
- Record Type:
- Journal Article
- Title:
- Excellent long-term results of the Müller acetabular reinforcement ring in primary cup revision: A single-center study of 259 cases after a mean of 10 years' follow-up. (2nd November 2017)
- Main Title:
- Excellent long-term results of the Müller acetabular reinforcement ring in primary cup revision
- Authors:
- Mueller Greber, Pascal
Manzoni, Isabella
Ochsner, Peter E
Ilchmann, Thomas
Zwicky, Lukas
Clauss, Martin - Abstract:
- Abstract : Background and purpose — The original Müller acetabular reinforcement ring (ARR) was developed to be used for acetabular revisions with small cavitary and/or segmental defects or poor acetabular bone quality. Long-term data for this device are scarce. We therefore investigated long-term survival and radiographic outcome for revision total hip arthroplasty using the ARR. Patients and methods — Between October 1984 and December 2005, 259 primary acetabular revisions using an ARR were performed in 245 patients (259 hips). The mean follow-up time was 10 (0–27) years; 8 hips were lost to follow-up. The cumulative incidence for revision was calculated using a competing risk model. Radiographic assessment was performed for 90 hips with minimum 10 years' follow-up. It included evaluation of osteolysis, migration and loosening. Results — 16 ARRs were re-revised: 8 for aseptic loosening, 6 for infection, 1 for suspected infection, and 1 due to malpositioning of the cup. The cumulative re-revision rate for aseptic loosening of the ARR at 20 years was 3.7% (95% CI 1.7–6.8%). Assuming all patients lost to follow-up were revised for aseptic loosening, the re-revision rate at 20 years was 6.9% (95% CI 4.1–11%). The overall re-revision rate of the ARR for any reason at 20 years was 7.0% (95% CI 4.1–11%). 21 (23%) of the 90 radiographically examined ARR had radiographic changes: 12 showed isolated signs of osteolysis but were not loose; 9 were determined loose on follow-up, ofAbstract : Background and purpose — The original Müller acetabular reinforcement ring (ARR) was developed to be used for acetabular revisions with small cavitary and/or segmental defects or poor acetabular bone quality. Long-term data for this device are scarce. We therefore investigated long-term survival and radiographic outcome for revision total hip arthroplasty using the ARR. Patients and methods — Between October 1984 and December 2005, 259 primary acetabular revisions using an ARR were performed in 245 patients (259 hips). The mean follow-up time was 10 (0–27) years; 8 hips were lost to follow-up. The cumulative incidence for revision was calculated using a competing risk model. Radiographic assessment was performed for 90 hips with minimum 10 years' follow-up. It included evaluation of osteolysis, migration and loosening. Results — 16 ARRs were re-revised: 8 for aseptic loosening, 6 for infection, 1 for suspected infection, and 1 due to malpositioning of the cup. The cumulative re-revision rate for aseptic loosening of the ARR at 20 years was 3.7% (95% CI 1.7–6.8%). Assuming all patients lost to follow-up were revised for aseptic loosening, the re-revision rate at 20 years was 6.9% (95% CI 4.1–11%). The overall re-revision rate of the ARR for any reason at 20 years was 7.0% (95% CI 4.1–11%). 21 (23%) of the 90 radiographically examined ARR had radiographic changes: 12 showed isolated signs of osteolysis but were not loose; 9 were determined loose on follow-up, of which 5 were revised. Interpretation — Our data suggest that the long-term survival and radiographic results of the ARR in primary acetabular revision are excellent. … (more)
- Is Part Of:
- Acta orthopaedica. Volume 88:Number 6(2017)
- Journal:
- Acta orthopaedica
- Issue:
- Volume 88:Number 6(2017)
- Issue Display:
- Volume 88, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 88
- Issue:
- 6
- Issue Sort Value:
- 2017-0088-0006-0000
- Page Start:
- 619
- Page End:
- 626
- Publication Date:
- 2017-11-02
- Subjects:
- Orthopedics -- Periodicals
616.7005 - Journal URLs:
- http://informahealthcare.com/loi/ort ↗
http://www.tandfonline.com/toc/iort20/current ↗
https://actaorthop.org/actao/index ↗
http://www.tandfonline.com/ ↗
http://journalsonline.tandf.co.uk/app/home/journal.asp?wasp=65168817ff044fea9c5b577f1cfe2186&referrer=parent&backto=linkingpublicationresults, 1:113260, 1 ↗ - DOI:
- 10.1080/17453674.2017.1361137 ↗
- Languages:
- English
- ISSNs:
- 1745-3674
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0642.055000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8304.xml