Diagnostic Contribution of Donor-Specific Antibody Characteristics to Uncover Late Silent Antibody-Mediated Rejection—Results of a Cross-Sectional Screening Study. Issue 3 (March 2017)
- Record Type:
- Journal Article
- Title:
- Diagnostic Contribution of Donor-Specific Antibody Characteristics to Uncover Late Silent Antibody-Mediated Rejection—Results of a Cross-Sectional Screening Study. Issue 3 (March 2017)
- Main Title:
- Diagnostic Contribution of Donor-Specific Antibody Characteristics to Uncover Late Silent Antibody-Mediated Rejection—Results of a Cross-Sectional Screening Study
- Authors:
- Eskandary, Farsad
Bond, Gregor
Kozakowski, Nicolas
Regele, Heinz
Marinova, Lena
Wahrmann, Markus
Kikić, Željko
Haslacher, Helmuth
Rasoul-Rockenschaub, Susanne
Kaltenecker, Christopher C.
König, Franz
Hidalgo, Luis G.
Oberbauer, Rainer
Halloran, Philip F.
Böhmig, Georg A. - Abstract:
- Abstract : Background: Circulating donor-specific antibodies (DSA) detected on bead arrays may not inevitably indicate ongoing antibody-mediated rejection (AMR). Here, we investigated whether detection of complement-fixation, in parallel to IgG mean fluorescence intensity (MFI), allows for improved prediction of AMR. Methods: Our study included 86 DSA+ kidney transplant recipients subjected to protocol biopsy, who were identified upon cross-sectional antibody screening of 741 recipients with stable graft function at 6 months or longer after transplantation. IgG MFI was analyzed after elimination of prozone effect, and complement-fixation was determined using C1q, C4d, or C3d assays. Results: Among DSA+ study patients, 44 recipients (51%) had AMR, 24 of them showing C4d-positive rejection. Although DSA number or HLA class specificity were not different, patients with AMR or C4d + AMR showed significantly higher IgG, C1q, and C3d DSA MFI than nonrejecting or C4d-negative patients, respectively. Overall, the predictive value of DSA characteristics was moderate, whereby the highest accuracy was computed for peak IgG MFI (AMR, 0.73; C4d + AMR, 0.71). Combined analysis of antibody characteristics in multivariate models did not improve AMR prediction. Conclusions: We estimate a 50% prevalence of silent AMR in DSA+ long-term recipients and conclude that assessment of IgG MFI may add predictive accuracy, without an independent diagnostic advantage of detecting complement-fixation.Abstract : Background: Circulating donor-specific antibodies (DSA) detected on bead arrays may not inevitably indicate ongoing antibody-mediated rejection (AMR). Here, we investigated whether detection of complement-fixation, in parallel to IgG mean fluorescence intensity (MFI), allows for improved prediction of AMR. Methods: Our study included 86 DSA+ kidney transplant recipients subjected to protocol biopsy, who were identified upon cross-sectional antibody screening of 741 recipients with stable graft function at 6 months or longer after transplantation. IgG MFI was analyzed after elimination of prozone effect, and complement-fixation was determined using C1q, C4d, or C3d assays. Results: Among DSA+ study patients, 44 recipients (51%) had AMR, 24 of them showing C4d-positive rejection. Although DSA number or HLA class specificity were not different, patients with AMR or C4d + AMR showed significantly higher IgG, C1q, and C3d DSA MFI than nonrejecting or C4d-negative patients, respectively. Overall, the predictive value of DSA characteristics was moderate, whereby the highest accuracy was computed for peak IgG MFI (AMR, 0.73; C4d + AMR, 0.71). Combined analysis of antibody characteristics in multivariate models did not improve AMR prediction. Conclusions: We estimate a 50% prevalence of silent AMR in DSA+ long-term recipients and conclude that assessment of IgG MFI may add predictive accuracy, without an independent diagnostic advantage of detecting complement-fixation. Abstract : The authors report their experience on 86 DSA+ kidney transplant recipients with available screening biopsies. They confirm that about 50% of these patients do experience subclinical ABMR and compare the prognostic information given by IgG MFI level, C1q- and C3d-fixing properties of DSAs. … (more)
- Is Part Of:
- Transplantation. Volume 101:Issue 3(2017)
- Journal:
- Transplantation
- Issue:
- Volume 101:Issue 3(2017)
- Issue Display:
- Volume 101, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 101
- Issue:
- 3
- Issue Sort Value:
- 2017-0101-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-03
- Subjects:
- Transplantation of organs, tissues, etc -- Periodicals
Transplantation immunology -- Periodicals
617.95 - Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/TP.0000000000001195 ↗
- Languages:
- English
- ISSNs:
- 0041-1337
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9024.990000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8283.xml